CT100G Series Inverter Safety precautions
- 4 -
Others
» This inverter is not suitable for the occasions when the specifications exceed
those specified in this manual. If you have special requirements, please
contact our technical department.
» The inverter is equipped with surge suppressors inside, which can protect it
from the lightning. It is necessary to mount external surge suppressors at the
power input side of the inverter in high lightning incidence areas.
» When the conductors between the inverter and the motor exceed 100m, it is
recommended to mount the output reactors to avoid overcurrent caused by
excessive distributed capacitance.
» Do not mount the compensation capacitors and the surge absorbers at the
output sides of the inverter. Otherwise, it may cause damage to the inverter
due to overheating.
» Mounting the input or output reactors, special filters and magnetic rings at
the input or output sides of the inverter can effectively reduce the noise and
thus avoid interference to other devices.
» Non-professionals are not allowed to perform withstand voltage tests on the
inverter, , otherwise damage to the inverter may occur.
» Deal with the devices as industrial effluent after scrapping. Burning is strictly
prohibited, otherwise an explosion may occur.
» The cooling effect of the inverter is reduced and the electrolytic capacitor
electrolyte is also volatile in high altitude areas, which will shorten the life of
the inverter. Check the altitude of the actual usage site is below 1000m. If
higher than 1000m, reduce 1% for every additional 100m.