Solar Pump Inverter Chapter 2 Solar Pump Inverter
11
2.3.2 CT112A series parameters
CT112A Solar Pump Inverter
CT112A-2S/2T-XXX 0.7 1.5 2.2
Rated output power(kW
0.7 1.5 2.2
Max. DC input currentA
9 12 12
Rated AC input current—AC typeA
9.3 15.7 24
Rated output currentA
4.5 10 14
Note: Output current is defined as rated value at single 220V output voltage, and output
current at three phase output is counted additionally according to the power.
Mode
CT112A-2S-0.7
CT112A-2T-0.7
CT112A-2S-1.5
CT112A-2T-1.5
CT112A-2S-2.2
CT112A-2T-2.2
DC INPUT
Max. DC voltage(V) 450
Starting voltage(V)
80
100
Min. Operation voltage(V) 60 80
Recommended MPPT
voltage(V)
80~400 100~400
Input channel One channel:MC4
Max. DC input current(A)
9
12
Bypass AC input (model supports mains input)
Input voltage(Vac)
220/230/240(1PH)
-15%~+10%
Input frequencyHz 47~63
AC input terminal
1P2L
AC output
Rated
W
750
1500
2200
Rated currentA
5.11PH
4.23PH
10.21PH
7.53PH
141PH
103PH
Output voltage(Vac)
0~input voltage
Output wiring mode
1P2L/2P3L/3P3L
Output frequency
Hz
1~400
Control performance
Control mode
MPPT
Motor type
Asynchronous motor
Other parameters
Dimension
L*W*H
)(
mm
314*280*128
Protection level
IP54
Cooling mode
Natural cooling
HMI
External LED keypad
Communication terminal
External communication
RS485/3 digital inputs
Operation environment
Ambient temperature
-25
~60℃
derate when the temperature is above 45
Operation altitude
3000 m
derate when the altitude is above 2000m
Warranty
18 months