Solar Pump Inverter Chapter 4 Function Parameters
27
Chapter 4 Function Parameters
4.1 The Basic Function Parameters
The symbols in the function code table are described as follows:
"
○" means the value of this parameter can be modified in stop and running status of drive;
"☆" means the value of this parameter cannot be modified when drive is running;
"
●" means this parameter is a measured value that cannot be modified;
Default: The value when restored to factory default. Neither measured parameter value nor
recorded value will be restored.
Setting Range: the scope of setting and display of parameters.
Code Name Description
Factory
Attri
F00 Group: Basic function
F00.01
Command Source
Selection of
Run/Start
0:Operation Panel(LED off)
1:Terminal Panel(L/R on)
2:Computer Communications(L/R
)
1 ○
F00.03 Maximum frequency F00.04~600.00Hz 50.00Hz ☆
~
☆
F00.05 Lower frequency limit 0.00 Hz~F00.04 0.00Hz ☆
F00.06 Frequency setting
0: keypad digital setting
0 ○
F00.11 Acceleration Time 0 0.0s~3600.0s Model Set ○
F00.13 Run direction
0: positive
1: reverse
2: prohibit reverse
0 ☆
F00.17 Inverter type
0:G type
1:P type
0 ☆
F00.18 Restore parameters
0:No action
1:Restore factory setting
:
0 ☆
F01 Group: Start and stop control
F01.01 Starting frequency 0.00~50.00Hz
0.50Hz
(CT112-4T)
20.00Hz
(CT112-2S)
0.00Hz
☆
F01.02
Hold time of starting
frequency
0.0~50.0s 0.0s ☆