Solar Pump Inverter Chapter 4 Function Parameters
28
Code Name Description
Factory
Default
Attri
bute
F01.08 Stop mode selection
0Deceleration stop
1Freewheel stop
0
(CT112)
1
(CT112A)
F01.13
Dead time of
FWD/REV
0.0~3600.0s 0.0s
F01.14
Switch mode of
FWD/REV
0switch after zero frequency
1switch after starting frequency
2
delay and switch after stop speed
0
F01.15 Stop speed 0.00~100.00Hz
10.00HZ
(CT112)
0.50 Hz
(CT112A)
F01.18
Terminal Control
When Power-On
0Terminal Command Enabled
1
Terminal Command Disabled
1
F01.19
Actuation when
running frequency is
less than lower limit
frequency
0: run at lower limit frequency
1: stop
2: stand-by
0
F01.20
Delay time of
dormancy wake up
0.0~3600.0s 0.0s
F01.21
Restart when
Power-off
0Forbid to Restart
1Allow to restart
1
F01.22 Waiting time for
restart after power-off
0.0~3600.0s 60.0s
F01.23
Delay time of start
0.0~60.0s
60.0s
F01.24
Wait Time of Restart
When Power-off
0.0~100.0s 0.0s
F02 Group Motor parameter
F02.00
Motor1 type
0
Asynchronous motor
0
F02.01 Motor 1 Rated Power 0.1kW~3000.0kW Model Set
F02.02
Motor 1 Rated
Frequency
0.00Hz~F00.03 50.00Hz
F02.03
Motor 1 Rated
Rotational Speed
1RPM~36000RPM Model Set
F02.04
Motor 1 Rated
Voltage
0V~1200V Model Set
F02.05
Motor 1 Rated
Current
0.8A~6000.0A Model Set
F02.06
Stator resistance of
asynchronous motor
0.001~65.535Ω Model Set
F02.07
Rotor resistance of
asynchronous motor
0.001~65.535Ω Model Set
F02.08
Inductance of
asynchronous motor
0.1~6553.5mH Model Set
F02.09
Mutual inductance of
asynchronous motor
0.1~6553.5mH Model Set
F02.10
Non-load current of
asynchronous motor
0.1~6553.5A Model Set