Solar Pump Inverter Chapter 4 Function Parameters
28
Code Name Description
Factory
Attri
F01.08 Stop mode selection
0:Deceleration stop
1:Freewheel stop
0
(CT112)
1
(CT112A)
○
F01.13
Dead time of
FWD/REV
0.0~3600.0s 0.0s ○
F01.14
Switch mode of
FWD/REV
0:switch after zero frequency
1:switch after starting frequency
:
delay and switch after stop speed
0 ○
F01.15 Stop speed 0.00~100.00Hz
10.00HZ
(CT112)
0.50 Hz
(CT112A)
○
F01.18
Terminal Control
0:Terminal Command Enabled
:
Terminal Command Disabled
1 ○
F01.19
running frequency is
less than lower limit
0: run at lower limit frequency
1: stop
2: stand-by
0 ☆
F01.20
Delay time of
0.0~3600.0s 0.0s ☆
F01.21
Restart when
Power-off
0:Forbid to Restart
1:Allow to restart
1 ○
F01.22 Waiting time for
0.0~3600.0s 60.0s ○
F01.23
Delay time of start
○
F01.24
Wait Time of Restart
0.0~100.0s 0.0s ○
F02 Group Motor parameter
:
F02.01 Motor 1 Rated Power 0.1kW~3000.0kW Model Set ☆
F02.02
Motor 1 Rated
0.00Hz~F00.03 50.00Hz ☆
F02.03
Motor 1 Rated
Rotational Speed
1RPM~36000RPM Model Set ☆
F02.04
Motor 1 Rated
0V~1200V Model Set ☆
F02.05
Motor 1 Rated
Current
0.8A~6000.0A Model Set ☆
F02.06
Stator resistance of
0.001~65.535Ω Model Set ○
F02.07
Rotor resistance of
asynchronous motor
0.001~65.535Ω Model Set ○
F02.08
Inductance of
0.1~6553.5mH Model Set ○
F02.09
Mutual inductance of
asynchronous motor
0.1~6553.5mH Model Set ○
F02.10
Non-load current of
0.1~6553.5A Model Set ○