5 PREPARE FOR INSTALLATION
Failure to obey the following warnings could result in property damage, serious
injury, or death:
FLOOD HAZARD. For toilets that use raw-water systems: Do not install a raw-water pump
controlled by an automatic demand switch.
SHOCK OR FIRE HAZARD. Use the recommended fuse, circuit breaker, and wire size. Failure
to comply could result in a fire.
5.1 Laying out the fresh-water system
9
Vacuum Toilet
Vacuum Generator
Waste Holding Tank
Flush Switch/
Status Panel
Discharge
Pump
Dockside
Discharge
Holding Tank
Status Panel
Vent Filter
Seacock
Overboard
Discharge
Air Vent
I
Use cold water only. Install a shut-off valve in the water line for maintenance purposes.
5.2 Wiring/electronic control module connections
I
Read before proceeding:
There must be a circuit breaker or fuse for every toilet.
For marine applications, follow ABYC guidelines.
For RV applications, refer to ANSI/RVIA LV and NFPA70/NEC standards (U.S.A.)
or CEC I and II standards (Canada) for the recommended wire gauge. Refer to ”1.3
Supplemental directives” on page 3.
Use tinned, stranded copper wire.
Use crimp-type wire connections. Do not use wire nuts, as wire nuts can corrode.
5.3 Planning the electrical connections
Plan all component locations so that the wires are installed in locations that will always
remain dry.
I
Several flush-switch assembly options are available from Dometic. Follow the instructions
included with each flush switch assembly.