Installation Dometic 4300/4400 Series Toilets
5 Installation
5.1 Toilet installation
Note
If replacing an existing gravity-discharge toilet, make sure the center of the existing
discharge ange is at least 10 inches (254 mm) from the back wall, then proceed to
Step 5 for proper positioning of water line and electrical wiring.
1. Carefully unpack the toilet bowl and oor ange adapter.
2. Position the ceramic bowl in the space intended. Conrm that adequate clearance is available
for using the ush handle and opening the seat and lid.
3. Mark the oor at the rear corners of the toilet bowl (g.
3
). Measure the distance between
the two marks and divide by 2 to nd the toilet centerline. Mark the oor at the rear wall for the
centerline.
4. Place a carpenter’s square against the back wall, and draw a center line on the oor at least
14 inches (356 mm) long (g.
4
). Mark the centerline for the oor ange at 10 inches (254 mm)
from the wall (g.
5
). Add 0.25 in. (6 mm) to distance from wall if installing model with
hand sprayer attached to toilet.
3
4
5
5a. For through-the-oor water line and electrical wires, mark another centerline 6 inches (152 mm)
from the back wall (g.
6
).
5b. For through-the-wall water line and electrical wires, mark a centerline 8 inches (203 mm) up from
the oor centerline (g.
7
).
6. Make a 4-3/4 inch (121 mm) diameter hole (for most oor anges) or a 5-1/8 inch (130 mm)
diameter hole (for swivel joint oor ange) at the centerline mark furthest from the wall. Make a
1 inch (25 mm) hole at the mark closer to the wall for the water line and electrical wires (g.
8
).
Caution
The preferred oor ange installation method is to mount the oor ange directly on the
nished oor. However, if the bottom of oor ange and bottom of ceramic toilet must be
mounted at different heights, the oor ange must be mounted within 3/8 inch (10 mm) of
the bottom of the toilet (see illustrations on next page) or leakage may result.
6
7
8

Other manuals for Dometic 4300 Series