SYSTEM CHECKOUTSYSTEM CHECKOUT
SYSTEM CHECKOUTSYSTEM CHECKOUT
SYSTEM CHECKOUT: Verify that all features of
the installed system work. Check fan speeds,
cooling mode, furnace (if connected) and heat
strip. If the features do not work, check all wiring
and confirm that the correct options have been
selected on the Electronic Control Box. (See
paragraph 7.E)
2)
SYSTEM CONFIGURATIONSYSTEM CONFIGURATION
SYSTEM CONFIGURATIONSYSTEM CONFIGURATION
SYSTEM CONFIGURATION: If all features are
functioning, perform the following configuration
procedure:
a. Simultaneously depress the
UPUP
UPUP
UP and
DOWNDOWN
DOWNDOWN
DOWN
pushbuttons on the
Comfort Control CenteComfort Control Cente
Comfort Control CenteComfort Control Cente
Comfort Control Center
for at least one second. This completes the
system configuration.
I.I.
I.I.
I.
INSTALLATION OF RETURN AIR COVERINSTALLATION OF RETURN AIR COVER
INSTALLATION OF RETURN AIR COVERINSTALLATION OF RETURN AIR COVER
INSTALLATION OF RETURN AIR COVER
1. Remove Return Air Grille from the Return Air Cover.
2. Place the Return Air Cover up to Ceiling Template.
3. Install Cover to Template with #8 x 3/8" blunt point
phillips head screws provided (6 required).
4. Reinstall Return Air Grille into Return Air Cover.
5. Install two (2) hole plugs into screw holes in back of
return air grille. Align tabs with mating notches and
snap into place.
H.H.
H.H.
H.
COMPLETE UNIT WIRE CONNECTIONSCOMPLETE UNIT WIRE CONNECTIONS
COMPLETE UNIT WIRE CONNECTIONSCOMPLETE UNIT WIRE CONNECTIONS
COMPLETE UNIT WIRE CONNECTIONS
1. Connect the air conditioner ribbon cable connector to
the thermostat cable end connector. The connectors
are polarized and will easily snap together.
DO NOTDO NOT
DO NOTDO NOT
DO NOT
FORCE.FORCE.
FORCE.FORCE.
FORCE.
Return
Air Cover
Hole
Plugs
Return
Air
Grille