3
Model Nominal Electrical Compressor Compressor Fan Motor Fan Motor SCFM-High Total Refrigerant Minimum AC Circuit Installed Minimum
No. Capacity Rating Rated Load Locked Rated Load Locked Speed Static R-22 (Oz.) Wire Size* Protection Weight Generator
(BTU/HR) Amps Rotor Amps Rotor Max/Min Max/Min ***User (Pounds) Size**
Cooling Amps Amps W.C. Supplied 1Unit/2Units
620515.321 13,500 115 VAC, 12.4 60.0 3.1 8.8 335 /250 0.12/0.65 15.5 12AWG 20 Amp 102 3.5 KW/5.0 KW
620515.326 13,500 60 Hz., 1 PH 12.4 60.0 3.1 8.8 335/250 0.12/0.65 15.5 Copper 20 Amp 102 3.5 KW/5.0 KW
620515.421 13,500 11.5 50.0 3.1 8.8 335/250 0.12 / 0.65 17.0 Up To 24' 20 Amp 102 3.5 KW/5.0 KW
620525.321 13,500 12.4 60.0 3.1 8.8 335 / 250 0.12/0.65 15.5 20 Amp 102 3.5 KW/5.0 KW
620525.326 13,500 12.4 60.0 3.1 8.8 335/250 0.12/0.65 15.5 20 Amp 102 3.5 KW/5.0 KW
620525.421 13,500 11.5 50.0 3.1 8.8 335/250 0.12/0.65 17.0 20 Amp 102 3.5 KW/5.0 KW
620526.321 15,000 12.0 64.0 3.3 8.5 380/250 0.12/0.65 21.5 20 Amp 104 3.5 KW/5.0 KW
620526.326 15,000 12.0 64.0 3.3 8.5 380/250 0.12/0.65 21.5 20 Amp 104 3.5 KW/5.0 KW
630515.321 13,500 12.4 60.0 3.1 8.8 335/250 0.12/0.65 24.5 20 Amp 102 3.5 KW/5.0 KW
630515.326 13,500 12.4 60.0 3.1 8.8 335/250 0.12/0.65 24.5 20 Amp 102 3.5 KW/5.0 KW
630515.421 13,500 12.0 50.0 3.1 8.8 335/250 0.12/0.65 19.5 20 Amp 102 3.5 KW/5.0 KW
630516.321 15,000 12.0 64.0 3.3 8.5 380/250 0.12/0.65 21.5 20 Amp 104 3.5 KW/ 5.0 KW
630516.326 15,000 12.0 64.0 3.3 8.5 380/250 0.12/0.65 21.5 20 Amp 104 3.5 KW/5.0 KW
SPECIFICATIONS
* For wire length over 24 ft., consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications.
When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes
and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.