5 PREPARE FOR INSTALLATION
Failure to obey the following warnings could result in property damage, serious
injury, or death:
• FLOOD HAZARD. For toilets that use raw-water systems: Do not install a raw-water pump
controlled by an automatic demand switch.
• SHOCK OR FIRE HAZARD. Use the recommended fuse, circuit breaker, and wire size. Failure
to comply could result in a fire.
5.1 Laying out the fresh-water system
8100 Series
11
Macerator Toilet
Holding Tank
(cut-away view)
Flush-
Switch
Panel
Discharge
Pump
Deck
Discharge
“Full” Level
Probe (optional)
Vent
Fitting
Seacock
0.5" (13 mm)
Fresh Water Hose
Vent
Filter
8500, 8600, 8700, and 8900 Series
12
Macerator Toilet
Holding Tank
(cut-away view)
Flush Switch
Discharge
Pump
Deck
Discharge
Control
Module
“0.75” & “Full”
Level Probes (optional)
Vent
Fitting
Seacock
0.5" (13 mm)
Fresh Water Hose
Vent
Filter
I
Use cold water only. Install a shut-off valve in the water line for maintenance purposes.
5.2 Laying out the raw-water system
• A separate pump is required for raw-water systems.
• If the raw-water pump draws more than 18 amps of current, a 12 or 24 VDC electrical relay
must be installed.
• The pump is activated by the electrical signal from the toilet’s electronic control module that
would operate the integral water valve in a fresh water system.