CB, RHD Installing and connecting the cooling device
11
Determine the required cross section of the cable in relation to the cable length
according to fig. 4, page 4.
Key for fig. 4, page 4
A
Connect the red lead to the positive terminal.
Connect the black lead to earth.
Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage correspond (see type plate).
Connect the cooling device
As directly as possible to the pole of the battery or
To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at 24 V).
A
The cooling device is equipped with an electronic device to protect against
reversing the polarity and short circuits when connecting to a battery.
To protect the battery, the cooling device switches off automatically if the voltage is
insufficient (see table below).
Co-ordinate axis Meaning Unit
l Cable length m
Cable cross section mm²
NOTICE!
Make sure that the polarity is correct.
NOTICE!
Disconnect the cooling device and other power consuming devices
from the battery before connecting the battery to a quick charging
device.
Overvoltage can damage the electronics of the device.
12 V 24 V
Switch-off voltage
10.4 V 22.8 V
Switch-on voltage
11.7 V 24.2 V
RHD-CB--O-West.book Seite 11 Dienstag, 29. November 2016 11:52 11