Operation CoolFreeze
16
Using the fused DC plug
A
➤ Plug the DC connection cable (fig. 1 2, page 3) into the DC power supply inlet
of the cooler (fig. 3 3, page 3).
➤ Connect the connection cable to the DC power outlet.
Connecting to an AC power supply (e.g. in the home or office)
D
The coolers have an integrated multi-voltage power supply with priority circuit for
connecting to an AC voltage source. The priority circuit automatically switches the
cooler to power supply operation, if the device is connected to an AC power supply,
even if the DC connection cable is still attached.
When switching between the AC power supply and the battery supply, the red LED
may light up briefly.
➤ Plug the AC connection cable (fig. 1 3, page 3) into the AC power supply inlet
of the cooler (fig. 3 1,page 3).
➤ Connect the connection cable to the AC power outlet.
NOTICE! Danger of damage!
For protection of the device the DC cable supplied includes a fuse inside
the plug. Do not remove the fused DC plug.
Only use the DC cable supplied.
DANGER! Danger of electrocution!
•
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
•
If you are operating your cooler on board a boat from a power supply
connection of 120 V
w, you must install a residual current circuit
breaker between the 120 V AC power supply and the cooler.
Seek advice from a trained technician.
CF80_CF110-O-US.book Seite 16 Mittwoch, 30. August 2017 2:57 14