EasyManua.ls Logo

Dometic CVH - Page 26

Dometic CVH
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Troubleshooting CVH1525(G), CVC1700G
26
Fault Possible cause Remedy
No spark when spark
ignition button is
pressed.
Spark ignition defective ➤ Ignite burner manually.
➤ Contact an authorized
service agent for repair.
Burner does not ignite.
Spark ignition is working.
Gas supply valve is closed. ➤ Open the gas supply
valve.
Control button is set to “Flame
off”.
➤ Turn the control knob to
the desired position
between “Low flame” and
“high flame”.
Wrong control knob is turned. ➤ Ensure the control knob
that is turned corre-
sponds to the burner to
be light.
Burner ports are blocked. ➤ Remove, clean and rein-
sert the burner.
Burner goes out when
control knob is released
Control knob is not set between
the position “Low flame” and
“high flame”.
➤ Turn the control knob to
the desired position
between “Low flame” and
“high flame”.
Control knob not held down
long enough for flame safe-
guard to engage.
➤ Press and hold the control
knob for 5 s so that the
flame safeguard can be
activated.
Faulty connection or defective
flame safeguard.
➤ Contact an authorized
service agent for repair.
Uneven flame pattern or
slight flame lifting
Burner ports are blocked. ➤ Remove, clean and rein-
sert the burner.
At minimum flame set-
ting, the flame is too high.
Incorrect setting of the regula-
tor.
➤ Contact an authorized
service agent for repair.
Gas supply pressure too high.
Wrong injection valve installed.