EasyManua.ls Logo

Dometic DOTRC17B - Magnetron Removal and Installation; Magnetron Replacement Precautions

Dometic DOTRC17B
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-8
D. REMOVING MAGNETRON
(Figures 11 Through 13b)
(1) Remove the vent grille by loosening two screws.
(Figure 11)
(2) Remove the outside case. See page 7-6.
(3) Remove four tap tite screws securing the
magnetron to the wave guide.
(4) Disconnect the leadwire.
(5) Remove the magnetron VERY CAREFULLY.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit
of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
Figure 11
Figure 13-a Figure 13-b
Controller
(3 screws)
Door
Mounting
Plate
(1 or 2 screws)
Out Case
Mount,All
Vent Grille
Figure 12