EasyManua.ls Logo

Dometic DOTRC17B - Door and Ventilation System Service; Assembling the Oven Door; Removing the Ventilation Motor; Replacing the Humidity Sensor

Dometic DOTRC17B
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-10
H. ASSEMBLING DOOR
(1) When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly
parallel to the chassis. Also adjust so the door has no
play between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
I. REMOVING THE VENTILATION MOTOR
(1) Remove the mounting plate by loosening
mounting plate screws (1 or 2 screws)
securing it to the back plate.
(See Figure 18)
(2) Remove MOUNT, ALL by loosening one screw
securing the ventilation Motor and back plate.
(See Figure 19-a)
(3) Carefully pull the ventilation motor ASS'Y out of
the microwave oven. (See Figure 19-b)
J. REPLACING THE HUMIDITY SENSOR
(For sensor model only)
(1) Remove the sensor by removing two screws
securing it to the air duct. (See Figure 19-c).
(2) Mount the new humidity sensor to the air duct.
Space
Figure 19-c
(1 or 2 screws)
MOUNT, ALL
Figure 18
Figure 19-a
Figure 19-b