7-17
Normal:
Approximately
25 to 45 ohm
Normal:Approximately
Abnormal:
Infinite or several.
Normal:
Approximately 250 to 350
Kohm at 68 ± 35°F
Abnormal:
Infinite or several.
Normal: Approximately
Abnormal:
Infinite or several.
Normal: Approximately
at 68 ± 35°F
Abnormal:
Infinite or several.
COMPONENTS TEST RESULTS
VENTILATION MOTOR
DAMPER MOTOR (D.M)
TURNTABLE MOTOR (T.M)
STIRRER MOTOR (S.M)
THERMISTOR
HEATER ELEMENT
SENSOR
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
1. Remove the connector from PCB
2. Measure resistance across pins 1 & 3.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale:Rx1)
1. Remove the 3 pin connector from PCB.
2. Measure resistance across pins 1 & 2.
3. Across pins 2 & 3.
(ohm meter scale:Rx1)
D.M T.M S.M
2.3-3.5 2.6-3.5 100-170
Kohm Kohm ohm
Conv. HTR
15-25
1 & 2 2 & 3
3.1 Kohm