FreshJet3000 Installation
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
Ensure that the mains voltage supply has a residual current circuit breaker.
Make sure that the grounding cable of the air conditioner is connected to the
vehicle‘s grounding system.
There are two ways of installing the roof air conditioner:
Making a new opening (chapter “Making a new opening” on page 15). In this
case the opening must be reinforced by an appropriate frame.
Using an existing opening in the vehicle such as a roof hatch or replacing an
old air conditioner (chapter “Installing in an existing opening” on page 16).
8.2 Making a new opening
See fig. 5, page 4
Select an area at the centre on the roof between two longitudinal supports.
Mark the position and size of the opening (preferably 400 x 400 mm or
optionally 360 x 360 mm).
See fig. 6, page 4
Drill out the corners (A).
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (B).
Make sure no electrical power cables are damaged.
See fig. 7, page 5
Before installation, check whether the roof hole needs reinforcing.
If needed, remove the foam according to the width of your reinforcing rails
(not in scope of delivery) (A).
Fit the reinforcing rails (B).
If needed, fit a suitable H-frame to provide reinforcement to the roof.
FreshJet3000--INM.book Seite 15 Donnerstag, 12. März 2020 11:39 11