Disposal MFV5M, MF15
14
10 Disposal
➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
M
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
applicable disposal regulations.
11 Technical data
I
MF V5M
Connection voltage: 100 – 240 Vw, 50/60 Hz (Adapter)
Power consumption: max. 45 W
Cooling capacity: max. 30 °C under ambient temperature
Switch-off at approx. 4 °C (COLD mode)
Heating capacity: approx. 65 °C interior temperature
(fixed-point thermostat)
Capacity: 5 l
Climate class: T
Ambient temperature: +16 °C to +43 °C
Dimensions (W x H x D): 190 x 313 x 305 mm
Weight: 3.7 kg
Testing/certification:
NOTE
If the ambient temperature is above +34 °C (+93 °F), the minimum
temperature cannot be attained.
MFV5M-MF15-O-EN.book Seite 14 Dienstag, 1. August 2017 10:17 10