Typical Two Side Wall Vent Application. Always
Refer To Vent Instructions 3308666.xxx
* When dimension “D” exceeds “1”, it is necessary to add bafe (E)
above lower access vent as shown, for more efcient operation in
warm temperatures.
Model
No.
Min.
Vent
Height
A
Min Dim.
+1/4, -0
B
Min Dim.
C
Max
Dim.
C
Min Dim.
D*
Max
Dim.
E F
NDA 1402 63 27 - 1/16 5 - 1/8 8 4 - 5/8 1 44 - 1/2
NDE 1402 63 27 - 1/16 5 - 1/8 8 4 - 5/8 1 44 - 1/2
(Dimensions are in inches)
THE FAN PLACEMENT DIMENSION
TO THE REFRIGERATOR FLOOR
MUST BE MAINTAINED EVEN WHEN
THE UPPER VENT IS LOCATED
HIGHER THAN DIMENSION “A”