4445103632 19
Error indication
I
Poor cooling, increase in
interior temperature.Com-
pressor does not run (bat-
tery connection).
There is an interruption in the battery –
electronics connection.
Establish a connection.
The main switch is defective (if
installed).
Replace the main switch.
The additional supply line fuse has
blown (if installed).
Replace the supply line fuse.
The battery voltage is too low. Charge the battery.
The battery capacity too low. Replace the battery.
The cables are loose.
The contact is poor (corrosion).
Establish a connection.
The cable cross section is too small. Replace the cable.
The compressor is defective. Contact an authorized service agent.
Unusual noises. A component of the refrigerant circuit
cannot move freely (touching the wall).
Bend the component carefully away from
the obstruction.
There is a foreign object stuck between
the cooling unit and the wall.
Remove the foreign object.
Fan noise. Replace the fan.
Fault Possible cause Suggested remedy
NOTE
All errors are indicated by the error indicator LED flashing red (see chapter “Control and dis-
play elements” on page 13). The number of flashes depends on the type of fault. Each flash
lasts for one quarter of a second. After the sequence of flashes a pause follows.The sequence
for the fault is repeated every four seconds.
In ECO, PERFORMANCE and FREEZER mode, an additional beep sounds.
Flashing
frequency
Error Possible cause
1 Under or over voltage The supply voltage is outside of the set range.
2 Excessive fan current The fan load on the electronics unit is more than 1 A.
3 The motor doesn't start The rotor is jammed.
The pressure difference in the cooling system is too high.
4 Speed too low If the cooling system is overloaded, the minimum speed of
the motor cannot be maintained.
5 Overheating of the electronics unit If the cooling system is loaded too heavily or the tempera-
ture is set too high, the electronics can overheat.
Constantly Temperature sensor errors Temperature sensor is defective.

Other manuals for Dometic NRX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic NRX Series and is the answer not in the manual?

Dometic NRX Series Specifications

General IconGeneral
BrandDometic
ModelNRX Series
CategoryRefrigerator
LanguageEnglish

Related product manuals