The display shows the charging status.
If charging the battery pack with a solar panel, observe the following require-
ments:
Use without a solar controller:
Ensure that the solar panel outputs between 8 25 V DC and a maximum
charging current of 10 A.
Use with a solar controller:
Ensure the solar charger does not need a counter voltage from the battery
side to start charging. Ensure that the maximum charging current is 10 A
(check with the solar panel manufacturer).
6.4 Checking the charge level
Press the power button (fig. 2 1, page 3).
The display shows the battery state of charge as a percentage.
The symbol flashes when the battery capacity is below 20 %.
6.5 Connecting consumer devices
fig. 2, page 3
Open the cap for the desired device:
–USB devices (3)
–2-pin 12VDC socket outlet (4)
–12VDC socket (5)
Insert your device’s plug into the corresponding socket.
The symbol and the related output symbol light up.
6.6 Replacing fuses
Ensure that the battery pack is not connected to AC/DC or DC/DC charger.
Disconnect all loads.
Press the power button for at least 3 s to switch the battery pack off.
Undo the fuse holder.
Replace the fuse with a 20 A 3 AG glass-slow acting fuse.