Troubleshooting PR2000, PR2500
24
➤ Lift up the front panel slightly so that the hinge does not bear any load.
➤ Tighten the screws with 15 – 25 Nm.
8.5 Patching small holes in the fabric
You can patch any small holes in the fabric or parts where the coating has come off:
➤ Use a cotton cloth to rub around the damaged area with a small amount of liquid
vinyl plaster (ref. no. 9103104018, available from your service partner).
✓ The liquid vinyl plaster dissolves the coating. The coating seals the hole when it
dries.
➤ Wait until the area is dry before you retract the awning again.
9Troubleshooting
I
NOTE
If you are not able to rectify a fault with the help of the following table,
please contact the relevant service partner in your country (see the back
of the manual for the address).
Fault Possible cause Suggested remedy
PR2500 only:
The motor is not
responding to the
remote control.
The remote control
battery is flat.
Briefly press one of the buttons or
. If the remote control LED does not
light up, the battery is flat.
Replace the battery, see chapter
“Replacing the batteries of the remote
control and the wall switch (only
PR2500, optional)” on page 22.
The remote control is no
longer or not properly
set to the motor.
Reprogram the remote control, see the
installation manual.
No power supply
available
Check the electric connections.
The motor is defective. Retract the awning manually and
contact the service partner in the
respective country.
PR2000_PR2500-O-16S.book Seite 24 Donnerstag, 5. Oktober 2017 10:23 10