RC10.4 70, RC10.4 90
Refrigerator
Installation and Operating Manual. . . . . . . 13
Kühlschrank
Montage- und Bedienungsanleitung . . . . . 31
Réfrigérateur
Instructions de montage
et de service . . . . . . . . . . . . . . . . . . . . . . . . .49
Koelkast
Montagehandleiding en
gebruiksaanwijzing . . . . . . . . . . . . . . . . . . .69
EN
DE
FR
NL
REFRIGERATION
RC SERIES
RC10.4-IO-EN-DE-FR-NL.book Seite 1 Montag, 10. September 2018 11:15 11

Questions and Answers

  • Z
    Zachary PowersAug 7, 2025
    Why is my Dometic RC10.4 70 Refrigerator not cooling properly?
    • S
      Shannon HendersonAug 7, 2025
      If your Dometic Refrigerator isn't cooling well and the interior temperature is rising, consider these potential causes: The ambient temperature may be too high, or there might be insufficient ventilation. Try moving the refrigerator to a cooler location with better air circulation and clean the condenser. Also, a faulty fan can cause poor cooling, so replace the fan if necessary. If the battery capacity is exhausted, charge the battery.
  • J
    Jennifer HughesAug 12, 2025
    How to fix a Dometic RC10.4 70 that runs constantly?
    • A
      Amber FaulknerAug 12, 2025
      If your Dometic Refrigerator's compressor runs constantly, the thermostat may be faulty. In this case, change the thermostat.
  • M
    michael51Aug 22, 2025
    What to do if Dometic RC10.4 70 compressor is not running when connected to AC?
    • D
      Darren RushAug 22, 2025
      If your Dometic Refrigerator's compressor isn't running when connected to an AC supply, it could be due to a few reasons. Check for interruptions in the supply cable and establish a connection. If installed, the main switch or the additional supply line fuse might be faulty and need replacement. The electric circuit between the pins in the compressor might be interrupted, requiring compressor replacement. High ambient temperature, insufficient ventilation, or a dirty condenser can also cause this; consider moving the refrigerator to a cooler, well-ventilated area and cleaning the condenser. In some cases, the compressor itself may be defective, and require replacement.
  • D
    David WintersAug 27, 2025
    What to do if Dometic Refrigerator is making unusual noises?
    • V
      Veronica WeberAug 27, 2025
      If your Dometic Refrigerator is making unusual noises, it could be that a component of the refrigerant circuit is touching the wall, in this case, bend the component carefully away from the obstruction. Alternatively, a foreign body might be jammed between the cooling unit and a wall; if so, remove the foreign body.
  • T
    Thomas ParsonsSep 1, 2025
    Why Dometic RC10.4 70 Refrigerator motor does not start?
    • S
      Susan DominguezSep 1, 2025
      If the motor of your Dometic Refrigerator doesn't start, it could be due to a jammed rotor or a pressure difference in the cooling system that is too high (more than 5 bar).
  • M
    Mrs. Ashley ScottNov 16, 2025
    What to do if Dometic Refrigerator compressor does not run on battery?
    • A
      Anthony BradleyNov 16, 2025
      If the compressor of your Dometic Refrigerator doesn't run when connected to a battery, there could be several reasons. First, check for interruptions in the connection between the battery and the electronics, loose cables, or poor contact due to corrosion; in such cases, establish a secure connection. Also, the main switch or supply line fuse might be faulty and need replacement. Ensure the battery voltage isn't too low by charging it or replacing it if its capacity is insufficient. A cable with too small a cross-section should be replaced. Additionally, high ambient temperature, insufficient ventilation, a dirty condenser, or an interrupted electric circuit in the compressor can cause this issue; try moving the refrigerator to a cooler, well-ventilated location, cleaning the condenser, o...

Summary

Explanation of Symbols

DANGER! Safety Instruction

Critical safety instruction where failure to observe can cause death or serious injury.

WARNING! Safety Instruction

Safety instruction where failure to observe can cause death or serious injury.

Safety Instructions

General Safety

Covers general safety warnings, installation by qualified technicians, and handling of damaged cables.

Technical Description

Setting Up and Connecting the Refrigerator

Setting Up the Refrigerator

Provides guidelines for placing the refrigerator in a suitable dry, sheltered location away from heat sources.

Connecting the Cooling Device

Covers electrical connection, wiring, cable colors, battery connection, and AC mains connection.

Operation

Using the Refrigerator

Detailed instructions on operating the refrigerator, setting temperature, and conserving foodstuffs.

Cleaning and Maintenance

Troubleshooting

Compressor Not Running (Battery Connection)

Identifies faults, causes, and remedies when the compressor does not run on battery power.

Compressor Not Running (AC Supply)

Identifies faults, causes, and remedies when the compressor does not run on AC power.

Technical Data

Dometic RC10.4 70 Specifications

General IconGeneral
ModelRC10.4 70
Refrigeration TechnologyAbsorption
Rated Input Current (DC)10 A
Rated Input Power (DC)120 W
Number of Doors1
Total Volume70 liters
Power SourceAC/DC/Gas
Voltage12V DC, 230V AC
Gas Pressure (DIN900)30 mbar
TypeAbsorption refrigerator