Troubleshooting RC(S)(L)(D)10-Series
32
6.1 Error and warning indication
I
RC10.4T.70, RC10.4T.90, RCL10.4(E)T, RCD10.5(X)T, RCS10.5(X)T
Faults are indicated by a fault code with a warning symbol ( ) in the middle of the
TFT display.
If multiple faults occur, the fault codes scroll over in the middle of the display.
All faults of the WARNING (W) type are reset automatically once the fault has been
rectified.
All faults of the ERROR (E) type must be reset manually:
➤ Press the control knob for at least 2 seconds.
✔ A beep sounds.
✔ The error has been reset.
NOTE
All faults are indicated by a warning symbol, a fault ID and a beep. The
beeping lasts for 2 minutes and is repeated every 30 minutes until the
error has been rectified.
Code Audio alarm Fault Solution
W02 No Defective temperature sen-
sor in the refrigerator com-
partment
➤ Contact an authorized cus-
tomer service point.
E03 Yes Communication error ➤ Press the on/off button for at
least 2 seconds.
W04 No CI bus fault Resets automatically
W10 Yes Door open for more than
2minutes
➤ Close the door.
W11 Yes DC voltage <7.5 V Resets automatically
W19 Yes DC voltage <10.9 V Resets automatically
E32 Yes Outer fan overcurrent ➤ Press the on/off button for at
least 2 seconds.
E33 Yes Compressor does not start ➤ Press the on/off button for at
least 2 seconds.
E34 Yes Compressor overload ➤ Press the on/off button for at
least 2 seconds.
E35 Yes Thermal cut out compressor
controller unit
➤ Press the on/off button for at