RC(S)(L)(D)10-Series Troubleshooting
33
RC10.4S.70, RC10.4S.90, RC10.4P.100, RC10.4M.90,RCL10.4(E)S,
RCD10.5(X)S, RCS10.5(X)S
In the event of a fault, the warning LED (
) in the display flashes according to the
fault.
All faults of the WARNING (W) type are reset automatically once the fault has been
rectified.
All faults of the ERROR (E) type must be reset manually:
➤ Press for 2 seconds.
✔ A beep sounds.
✔ The error has been reset.
Number of
flashes
Audio alarm Fault type Fault Solution
continuous No W Defective temperature sen-
sor in the refrigerator com-
partment
➤ Contact an author-
ized customer ser-
vice point.
1 Yes W DC voltage <7.5 V Resets automatically
2 Yes E Outer fan overcurrent ➤ Press the on/off
button for at least
2seconds.
3 Yes E Compressor does not start ➤ Press the on/off
button for at least
2seconds.
4 Yes E Compressor overload ➤ Press the on/off
button for at least
2seconds.
5 Yes E Thermal cut out compressor
controller unit
➤ Press the on/off
button for at least
2seconds.
6 No W CI bus fault Resets automatically
– Yes W Door open for more than
2minutes
➤ Close the door.