Installation
5
4.5
1. The refrigerator must be level both directions
2. There sould be 20mm clearance to the wall
3. Ventilation must be provided as shown in
alternatives A,B,C or D
4. The ventilation duct must at least measure
105mm x the wt
dth of the refrigerator
5. Only the entire cooling unit must project into
the duct as shown
6 Air p
assing through the duct must not be
preheated by any source of heat
7. Ventilation grills, if used, must have openings
of at least 200cm² each
Please follow the installation details below
carefully. Guarantee is valid for products
installed as described only.
IMPORTANT:
200 cm²
20 mm
Where a socket outlet is used for the mains connection lead, the
outlet must be freely accessible.