Problem Possible cause Suggested remedy
No voltage present There is an interruption
in the battery –
electronics connection.
Establish a connection.
Main switch faulty (if
installed)
Replace the main switch.
Additional supply line
fuse has blown (if
installed).
Replace the supply line fuse.
Voltage is present but
the compressor doesn't
run (connected to AC
supply)
Ambient temperature
too high.
Insufficient ventilation Move the refrigerator to another
location.
Condenser is dirty. Clean the condenser.
Poor cooling, compres-
sor running for a long
time /continuously
Ambient temperature
too high
Insufficient ventilation Move the refrigerator to another
location.
Condenser is dirty. Clean the condenser.
Too cold or a great tem-
perature deviation
Defective compressor Replace compressor
RH440-CL440-460--IO-EN.book Seite 19 Donnerstag, 18. Mai 2017 6:29 18