INSTALLATION AND
OPERATING INSTRUCTIONS
REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION
RM 2352 RM 2353
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Dont touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information consult a qualified
installer, service agency or the gas
supplier.
AVIS
Cet appareil doit être répa
seulement par un réparateur
autorisé. Modification de
lappareil pourrait être
extrèmement dangeruse, et
pourrait causer mal ou mort.
Contents:
Page
Installation 4
Operating Instructions 9
Maintenance & Service 11
Corporate Office
2320 Industrial Parkway Elkhart, IN 46515
USA For Service Center Assistance CANADA
Service Office Call: 800-544-4881 Dometic Distribution Inc.
Dometic Corporation 866 Langs Drive
509 South Poplar Street Cambridge, Ontario
LaGrange, IN 46761 N3H 2N7 Canada
Phone: 260-463-4858 Phone: 519-653-4390
825 12 08-00
®
®
All manuals and user guides at all-guides.com
all-guides.com

Other manuals for Dometic rm 2352

Questions and Answers

  • J
    Juan BrownAug 2, 2025
    Why is my Dometic rm 2352 not cooling properly?
    • H
      Heather JonesAug 2, 2025
      Your Dometic Refrigerator might not be cooling well due to several reasons. The burner jet or burner could be dirty or clogged, requiring cleaning. Low LP gas pressure at the burner could be the cause; in this case, set the main regulator so the pressure does not drop below 11 inches of water column at the pressure tap. The burner might not be located properly under the flue tube and needs relocation, or the burner may be damaged and require replacement. Also, check the refrigerator's level and defrost it if needed. Ensure the flue baffle is properly inserted in the flue tube.
  • C
    Cheryl MeyerAug 12, 2025
    What to do if Dometic rm 2352 Refrigerator does not cool properly?
    • T
      Thomas KingAug 12, 2025
      If your Dometic Refrigerator isn't cooling properly, start by cleaning a dirty or clogged burner jet or burner. Ensure the refrigerator is level and defrost it. If the LP gas pressure is low at the burner, adjust the main regulator to maintain a pressure above 11 inches of water column at the pressure tap. Also, make sure the burner is correctly positioned under the flue tube, and that the flue baffle is properly inserted in the flue tube. If the burner is damaged, consider replacing it. For the thermostat settings, see Operating Instructions, part Thermostat.
  • T
    Tammy SmithAug 22, 2025
    How to fix Dometic Refrigerator that does not cool properly?
    • U
      udixonAug 22, 2025
      To fix a Dometic Refrigerator that isn't cooling properly, you can try the following: Clean a dirty or clogged burner jet or burner. Ensure the refrigerator is level and defrost it if necessary. If the LP gas pressure is too low at the burner, adjust the main regulator so that the pressure doesn't drop below 11 inches of water column at the pressure tap. Relocate the burner if it's not properly positioned under the flue tube. If the burner is damaged, replace it. Ensure the flue baffle is correctly inserted in the flue tube. For thermostat adjustments, consult the Operating Instructions, part Thermostat.

Summary

Control Panel Overview

Control Panel Legend

Details the function of each control knob and button on the refrigerator panel.

Installation Procedures

General Installation Instructions

Covers general requirements and certifications for installation in RVs and mobile homes.

Ventilation Heights and Clearances

Provides specific dimensions for ventilation heights and clearances around the refrigerator.

Gas Connection

Guidance on connecting the refrigerator to the LP gas supply line.

Testing LP Gas Safety Shutoff

Procedure to test the safety shutoff mechanism for the LP gas supply.

Electrical Connection

Details on connecting the refrigerator to 120V AC and 12V DC power sources.

Operating Instructions

Gas Operation

Step-by-step guide on how to start and operate the refrigerator using LP gas.

Electric Operation

Instructions for operating the refrigerator using 120V AC or 12V DC power.

Maintenance and Service

LP Gas System Checks

Procedure for checking LP gas connections for leaks and proper pressure.

Troubleshooting: Refrigerator Not Cooling