'96 TIS 46 141 238393
HO
CERTIFIED INSTALLATION
Certified installations require one roof vent and one
lower side vent.
For
"Certified
Vent
System Kits” see page
15.
For further information contact your dealer or distributor.
NOTE: The
upper
vent should be
centered over the
condenser
coil
at the beck of the
refrigerator.
I
I
I
Minimum
1
ventilation
,
FIG.
9
METHODS OF INSTALLATION
The
method of installation is shown in
FlG.
9. It is
essential
that all
maximum
or minimum dimensions are
strictly maintained as the performance
of the
refrigerator
is dependent on adequate flow of air over the rear of the
refrigerator,
VENTILATION HEIGHTS
r
Installation with roof
Minimum ventilation
vent and tower side vent
heights
in
Refrigerator
RM3662,
RM 3663
Inches
mm
57-3/4
1465
NOTE: Wood
Strip
MUST be in
place.
CLEARANCE%
Minimum clearances In inches to combustible materials
are:
G: Top 0
K:
Slde 0
L: Bottom 0
M:
Rear 0
N:
See NOTE: Clearance
"N”
below.
NOTE: Clearance
“M”
is between the
rearmost
part of
the refrigerator and the wall behind the refrigerator.
NOTE:
Clearance
“N"
is the distance between the bot-
tom of the lower vent to the roof material. For ventilation
height,
see
table
VENTILATION
HEIGHTS
See Figures 9, and 10.
RM 3662; RM 3963
1
63-3/4 1620