EasyManua.ls Logo

Dometic RM 3662 - Drain Water Hose Installation; LP Gas Safety Testing; Gas Shutoff Test Procedure

Dometic RM 3662
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
'98 TIS 46 141 238393
MO
FIG. 6
2.
Once the tower front
strip
is
slipped
under the hlnge,
the part is possible to swing
into
place
as shown in
FIG.
6.
3.
Secure the
refrigerator
and the
lower
front
strip
with
two screws:
One screw through the hinge, snd on the opposite
side
one
screw through the lower
front
strip. (FIG. 6).
STEP
2: Two screws Installed
In the
top frame.
The top
decoration
panel must be removed from the
refrigerator before the screws can be installed.
Open the upper door and gently push the tabs out of the
hole in the hinge
with
a flat blade screwdriver, (both
sides). See FIG. 7.
Carefully
tilt the top decoration panel and
lift
up to
remove from top frame. Be careful not to damage the
circuit board and wires.
FIG.
7
1
tnstatt the two screws in the top frame, the holes are
accessible
from underneath.
Seal the opening for the screws
with
aluminum tape.
Replace the top decoration
panel.
Be careful not to pinch
the
wires
behind the panel. Make
sure
the
tabs snap
back
into the holes in the hinge plate.
STEP 3:
Two
screws
Installed in the rear
base.
See FIG. 8.
Failure to
follow
the sequence In securing refrigerator in
enclosure can cause leakage between the frame and
cabinet.
Hole for
drain
water
ho
FIG. 8
Any
space
between the counter, storage area or
ceiling
and top of the refrigerator greater than
1-1/2
inches
should be blocked. The heal produced at the rear of the
refrigerator will become trapped in thts space, making
the top of the refrigerator hot and reduce the
efficiency
of the refrigerator.
Drain water hose
A hole must be drilled through flooring see FIG. 8.
The hole must be drilled in the cut out opening of the
base plate at the rear of the
refrigerator.
The
installer
MUST maks sure that the hose does not kink when run
through the floor. Seal around the hose that goes
through the
drilled
hole.
If
a longer hose than supplied Is
required to get the water to drain
outside
of the
vehicle,
the installer will have to supply the extra length of hose.
TESTING LP GAS SAFETY
SHUTOFF
The gas safety shut-off must be tested after the
refrigerator is connected to the LP
gas
supply.
To test the
gas
safety shut-off, proceed as follows:
1.
2.
3.
4.
5.
6.
7.
Start
the
refrigerator and switch to
the
GAS mode.
(see start up instructions).
Check that
the
gas flame Is
lit
and the GAS mode
Indicator
lamp (C) is on.
Close the manual gas shut-off valve at the back of
the refrigerator. (See FIG. 1).
Wait
for one minute. The CHECK indicator
lamp
(E)
should be on and
the
GAS mode indicator lamp (C)
should
be
off.
Remove protection cover (see
FIG.
1) and open the
manual gas shut-off valve. Do not change any
button
positions on
the
control
panel. Apply a non-corrosive
commercial
bubble solution to the burner jet orifice.
No bubbles
should
appear at the opening of the
burner jet orifice. The presence of
bubbles
indicates
a
defective
gas safety shut-off and service is
re-
quired.
If
no bubbles were present at the burner jet orifice,
it
should be rinsed
with
fresh water. Be careful not to
damage the burner jet orifice.
Replace
cover and
press the
main
power ON/OFF button (1) OFF and
back
ON. Normal
operation
of the burner should
return. Allow the burner to operate for a minimum of
five minutes.

Related product manuals