EasyManua.ls Logo

Dometic RM2201 Series - User Manual

Dometic RM2201 Series
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Foreword
This service manual is the result of the
dedication of The
Dometic
Corporation and
its engineers in giving service people the
necessary instruction for making accurate
analyses of certain conditions. Provided is
a diagnostic chart leading a qualified
mechanic into the service manual pages to
locate and solve symptoms which may
occur.
Dometic
has continued its
commitment in providing service people
with this, the most up-to-date information
about servicing
Dometic
RV accessories.
OS1
698
5/94
Question and Answer IconNeed help?

Do you have a question about the Dometic RM2201 Series and is the answer not in the manual?

Summary

Foreword

SECTION 1 OPERATION

1.1 RM2150 OPERATION

Details on operating the RM2150 refrigerator in gas and electric modes.

1.2 RM2190 OPERATION

Instructions for operating the RM2190 model on gas and 12V DC power.

1.3 RM2201 OPERATION

Steps for operating the RM2201 model using gas or electric power sources.

SECTION 2 AC VOLTAGE REQUIREMENTS

SECTION 3 AC COMPONENTS

HEATING ELEMENT

Description and testing procedure for the AC heating element, including resistance checks.

SECTION 4 DC VOLTAGE REQUIREMENTS

SECTION 5 DC COMPONENTS

5.1 SWITCH

How to check the continuity of the toggle and selector switches for proper function.

5.2 PIEZO IGNITER

Information on the piezo igniter, its function, and troubleshooting if no spark is produced.

5.3 ELECTRODE

How to inspect and test the electrode for proper spark gap and condition.

5.4 HEATING ELEMENT

Procedure for checking the DC heating element's resistance at room temperature.

5.5 THERMOSTAT (RM2201)

SECTION 6 LP GAS REQUIREMENTS

SECTION 7 LP GAS COMPONENTS

7.1 SHUT-OFF VALVE

Description of the LP gas shut-off valve and how to inspect it for obstructions.

7.2 FILTER

Explanation of the LP gas filter's role in protecting the thermostat and how to check for restrictions.

7.3 THERMOSTAT

7.4 SAFETY VALVE

7.5 THERMOCOUPLE

7.6 BURNER

7.7 FLUE BAFFLE

7.8 CROSSOVER TUBE

7.9 FLUE TUBE

7.10 ORIFICE

SECTION 8 WIRING

8.1 EXTERNAL WIRING

Guidelines for connecting the refrigerator's 120V AC power supply.

8.2 INTERNAL WIRING

Checks for internal wiring connections and verification against wiring diagrams.

SECTION 9 OTHER

9.1 LEVELING

Importance of proper leveling for absorption refrigerator operation and refrigerant flow.

9.2 VENTILATION

Requirements for coach vent system to dissipate heat and ensure proper cooling unit operation.

9.3 AIR LEAKS

9.4 DOOR POSITION

9.5 AMBIENT TEMPERATURE

9.6 COOLING UNIT

9.7 FOOD STORAGE

9.8 HIGH HUMIDITY

9.9 INTERIOR LINER SEAL TO FRAME

Summary

Foreword

SECTION 1 OPERATION

1.1 RM2150 OPERATION

Details on operating the RM2150 refrigerator in gas and electric modes.

1.2 RM2190 OPERATION

Instructions for operating the RM2190 model on gas and 12V DC power.

1.3 RM2201 OPERATION

Steps for operating the RM2201 model using gas or electric power sources.

SECTION 2 AC VOLTAGE REQUIREMENTS

SECTION 3 AC COMPONENTS

HEATING ELEMENT

Description and testing procedure for the AC heating element, including resistance checks.

SECTION 4 DC VOLTAGE REQUIREMENTS

SECTION 5 DC COMPONENTS

5.1 SWITCH

How to check the continuity of the toggle and selector switches for proper function.

5.2 PIEZO IGNITER

Information on the piezo igniter, its function, and troubleshooting if no spark is produced.

5.3 ELECTRODE

How to inspect and test the electrode for proper spark gap and condition.

5.4 HEATING ELEMENT

Procedure for checking the DC heating element's resistance at room temperature.

5.5 THERMOSTAT (RM2201)

SECTION 6 LP GAS REQUIREMENTS

SECTION 7 LP GAS COMPONENTS

7.1 SHUT-OFF VALVE

Description of the LP gas shut-off valve and how to inspect it for obstructions.

7.2 FILTER

Explanation of the LP gas filter's role in protecting the thermostat and how to check for restrictions.

7.3 THERMOSTAT

7.4 SAFETY VALVE

7.5 THERMOCOUPLE

7.6 BURNER

7.7 FLUE BAFFLE

7.8 CROSSOVER TUBE

7.9 FLUE TUBE

7.10 ORIFICE

SECTION 8 WIRING

8.1 EXTERNAL WIRING

Guidelines for connecting the refrigerator's 120V AC power supply.

8.2 INTERNAL WIRING

Checks for internal wiring connections and verification against wiring diagrams.

SECTION 9 OTHER

9.1 LEVELING

Importance of proper leveling for absorption refrigerator operation and refrigerant flow.

9.2 VENTILATION

Requirements for coach vent system to dissipate heat and ensure proper cooling unit operation.

9.3 AIR LEAKS

9.4 DOOR POSITION

9.5 AMBIENT TEMPERATURE

9.6 COOLING UNIT

9.7 FOOD STORAGE

9.8 HIGH HUMIDITY

9.9 INTERIOR LINER SEAL TO FRAME

Dometic RM2201 Series Specifications