EasyManua.ls Logo

Dometic RM2310 - Gas Safety Shutoff Testing

Dometic RM2310
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 6
MODEL RM2310 .
C. Close the gas
valve
by turning the knob
“A”
back
to
“OFF”
position. (See Fig. 7)
BLOCK FOR
HEATING
ELEMENT
When testing the gas supply system at test pressures
in excess of l/2 psig the refrigerator and its individual
shutoff valve must be disconnected from the gas supply
piping system.
Remove burner cover plate. (See Fig. 6). Open the
gasvalve by turning knob
“A”
to position GAS
without pushing the buttons C and
“D”. (See
Fig. 7). Apply commercial leak check bubble
solution to the burner jet. (See Fig. 8). Be careful
not to damage the burner jet.
Fig. 8
Clear Blue Color of Flame
When testing the gas supply system at pressures less
than or equal to l/2 psig the appliance must be isolated
from the gas supply piping by closing its individual
manual shutoff valve.
A
In casedetailed instructionson the installation and con-
nection to the gas supply are required, contact your
dealer or distributor.
Thermocouple
RM2310
9. Gas safety shutoff
Connection
Spring
Thermocouple
The gas safety shutoff must be tested after the
refrigerator is connected to the LP Gas supply.
To test the gas safety shutoff, proceed as follows:
H
Refrigerator with Piezo lgnitor
REFRIGERATORS WITH PIEZO
IGNITORS
D.
E.
Wait one (1) minute.
A.
B.
_
Start the refrigerator according to the instructions
for gas operation with piezo ignitor. See Section
8. Operating Instructions, kern 3. Gas Operation.
I
Burner jet
Check that the gas flame is lit. This can be
observed through reflector
“E”. (See
Fig. 7)

Other manuals for Dometic RM2310