1
THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THE
S1521, S1531, S1621, S1631, S1821, S1831, RM2607, RM2611, RM2807,
RM2811, RM3607, RM3807, RM3662, RM3663, RM3862, RM3863, RM4872
and RM4873 REFRIGERATORS.
SYMPTOM CAUSE
1. No operation - no panel lights Operation
DC Volts
Fuse
Wiring
Upper Circuit Board
Lower Circuit Board
2. No operation - has panel lights Operation
DC Volts
Thermistor
Fuses
Upper Circuit board
Wiring
Lower Circuit Board
3. No AC operation - operates on other mode(s) Operation
AC Volts
Fuse
Heating Element
Upper Circuit Board
Wiring
Lower Circuit Board
4. No DC operation - operates on other mode(s) Operation
DC Volts
Fuse
Heating Element
Upper Circuit Board
Wiring
Lower Circuit Board
5. No gas operation - operates on other mode(s) Operation
LP Gas
Manual Gas Valve
Igniter
High Voltage Cable
Electrode
Solenoid
Upper Circuit Board
Wiring
Lower Circuit Board
6. Insufficient cooling on all mode(s). Ventilation
Leveling
Ambient Temperature
Air Leaks
Thermistor
Cooling Unit
Thermistor Adjuster
Manual Compliments of
Northwest RV Supply
Printed From
http://www.nwrvsupply.com

Other manuals for Dometic RM2607

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM2607 and is the answer not in the manual?

Dometic RM2607 Specifications

General IconGeneral
BrandDometic
ModelRM2607
CategoryRefrigerator
LanguageEnglish

Related product manuals