INSTALLATION INSTRUCTIONS
A hole must be drilled through fl ooring and the installer needs
to make sure the hose does not kink when run through the fl oor.
Seal around the hose that goes through the drilled hole. If a
longer hose than supplied is required to get the water to drain
outside of the vehicle, the installer will have to supply the extra
Hook up to the gas supply line is accomplished at the manual
gas valve, which is furnished with a 3/8” SAE (UNF 5/8” -18)
male fl are connection. All completed connections should be ex-
amined for leaks using a solution of liquid detergent and water.
Be careful when working on or near the gas system.
Do not use an open fl ame to check for gas leaks!
The gas supply system must incorporate a pressure regulator
to maintain a supply pressure of not more than 11 inches water
column. When testing the gas supply system at test pressures:
- the refrigerator and its individual shutoff valve
must be disconnected from the gas supply piping system.
- the appliance must be isolated from the gas
supply piping system by closing its individual manual shut-
If detailed instructions on the installation and connection
to the gas supply are required, please contact your dealer or
Testing LP gas safety shut off
The gas safety shut off must be tested after the refrig-
erator is connected to LP gas supply.
To test the gas safety shut off, follow these steps:
Start the refrigerator and switch to GAS mode.
Check that the gas fl ame is lit and the GAS mode
Close the manual gas shutoff valve at the back of the
Wait for one minute. The CHECK indicator lamp
should be lit and the GAS mode indicator lamp
Remove the protection cover. Open the manual gas
shutoff valve. Do not change any button positions on
Apply a non corrosive commercial bubble solution
to the burner jet orifi ce. No bubbles should appear at
the opening of the burner jet orifi ce. The presence of
bubbles indicates a defective gas safety shutoff, and
If no bubbles were present at the burner jet orifi ce, it
should be rinsed with fresh water. Be careful not to
damage the burner jet orifi ce.
Turn off the refrigerator by pressing the ON/OFF
button and then, turn it back on. Normal operation of
the burner should return. Allow the burner to operate
for a minimum of fi ve minutes.
Hole for drain water hose