TEC29 EV Operating the generator
23
I
➤ Press the START button within 20 seconds and hold it down for 3 seconds.
✔ The display shows:
AUTO.
✔ The automatic mode is switched on.
I
8.9 Switching off the automatic mode
➤ Switch off the automatic mode switch (if available).
or
➤ Switch on the ignition.
✔ The display shows:
GEN OFF.
8.10 Operating two generators in parallel (optional)
I
You can independently turn each generator on and off. If the load is more than
2600 W, you can start both generators in parallel.
In case both generators are turned on:
Disconnect the load before switching off the system.
NOTE
If
GEN OFF appears on the display instead of AUTO?, the automatic mode
is not configured for your generator. If this is the case, contact the
specialist workshop which installed the generator and have the
automatic mode retrofitted.
NOTE
In automatic mode, you cannot start the generator with the
START button. The generator starts automatically.
You can switch the generator on and off with the automatic mode switch
(if available).
NOTE
The maximum allowed load for the parallel system is 4800 W.
Without the parallel cable or with a damaged parallel cable the proper
operation of the system is not guaranteed, especially in terms of load
sharing.