INSTALLATION AND OPERATING INSTRUCTIONS
JAKA HFD
JAKA HFS
ER-0170/1996
CGM-04/392

Questions and Answers

  • W
    Whitney DixonAug 2, 2025
    What to do if DOMUSA Jaka HFD burner does not ignite?
    • J
      Jacqueline RileyAug 2, 2025
      If the burner does not ignite, several factors could be at play. First, check if the fuel valve is closed and open it. Next, ensure the boiler has an electricity supply. A defective or dirty nozzle could also be the culprit—replace or clean it. Make sure the electrodes are correctly adjusted. If the timer is on automatic, switch it to manual. Lastly, check and correctly adjust the room or boiler thermostat.
  • S
    stephanie60Aug 11, 2025
    Why does my DOMUSA Jaka HFD have frequent cut-outs?
    • B
      Brian MannAug 11, 2025
      Frequent cut-outs in your DOMUSA Boiler can be caused by a few things. The nozzle may be defective and needs replacement. The photoelectric cell might be dirty, requiring cleaning. Also, check for any obstructions in the fume circuit and clean it if necessary. Finally, the installation oil filter or burner pump oil filter might be dirty and needs cleaning.
  • T
    Toni WhiteAug 17, 2025
    What to do if DOMUSA Jaka HFD Boiler radiator does not heat up?
    • S
      Samuel TurnerAug 17, 2025
      If your radiator isn't heating up, start by checking if the pump is turning. If it's blocked, unblock it. Also, there might be air in the hydraulic circuit. In this case, drain the installation and the boiler, ensuring the automatic air drain valve cap is always loose.
  • J
    Joel TaylorAug 26, 2025
    How to reduce excessive noise from DOMUSA Jaka HFD?
    • D
      Dr. Robert WatsonAug 26, 2025
      Excessive noise from your DOMUSA Boiler can stem from several issues. Ensure the burner is correctly adjusted. Eliminate any leaks if the flue is not correctly sealed. Examine the burner if the flame is unstable. If the flue is not insulated, make sure to suitably insulate it.

Summary

2 CONTROL ELEMENTS

3 INSTALLATION INSTRUCTIONS

4-7 Operational Procedures

4 Filling the Installation

Steps for filling the installation with water to the correct pressure.

5 Commissioning the Boiler

Requirements for starting up the boiler for warranty validation.

7 Safety Cut-outs

Details temperature and burner safety cut-out mechanisms and their reset procedures.

8 FUNCTIONING

Basic Operation Modes

How to set thermostats and switches for heating and hot water cycles.

12 BOILER MAINTENANCE

14 TECHNICAL CHARACTERISTICS

15 ELECTRICAL DIAGRAM

16 BURNER OPERATIONS

19 TROUBLESHOOTING

19.1 Burner Failures

Lists common burner failures, their causes, and solutions.

19.2 Boiler Failures

Lists common boiler failures, their causes, and solutions.

20 GENERAL WARRANTY CONDITIONS

DOMUSA Jaka HFD Specifications

General IconGeneral
BrandDOMUSA
ModelJaka HFD
CategoryBoiler
LanguageEnglish