A18
Light Fixture
Electrical work must be performed by a qualied electrician and comply with all applicable national and local codes.
Turn power off and lock out electrical power sources before performing service or maintenance work.
Do not install in classied hazardous atmospheres without an enclosure rated for the application.
Wire the xture following the wiring diagram included with the xture.
Afterlters
1. Place 1/4-in diameter rope-type sealant to the top ange
of the power module.
2. Position the afterlter plenum on the power module with
the vertically mounted afterlter facing over the booth.
3. Fasten using M8 x 20 mm bolts and at washers.
4. Install the afterlters in the afterlter frame.
5. Install HEPA lters with the lter gasket toward the inside
of the frame.
6. Install ASHRAE lters with the airow arrow pointing to the
outside.
7. Position the clamping straps and tighten the wing screws
securely.
Optional AfterFilter Installation
Delta P Control
For complete information, see the most current version of the Delta P Installation, Operation and Maintenance manual.
Delta P Plus Control
For complete information, see the most current version of the Delta P Installation, Operation and Maintenance manual.