7000XL Series
Digital Weight Indicator
Technical Manual
MAN330 – Rev 4.8 Doran Scales, Inc. www.doranscales.com
Question and Answer IconNeed help?

Do you have a question about the Doran 7000XL Series and is the answer not in the manual?

Summary

Introduction

Unpacking Your Scale

Instructions for safely unpacking the scale and precautions to prevent damage.

Scale Annunciators

Unit of Measure Indicator

Indicates the current unit of measure displayed on the scale.

Battery Status Indicator

Indicates low battery charge and charging status.

Center of Zero Indicator

Indicates when the scale is displaying a zero weight.

Motion Indicator

Indicates motion or instability of the weight on the platform.

Power Up

Basic Weighing Operation

Zeroing the Scale

Procedure for zeroing the scale and its function.

Unit Selection

How to select and change the current unit of measure.

Data Printing

Function for transmitting data to external devices.

Battery Operation

Power Off Modes

Methods for manually or automatically powering off the scale.

Low Battery Indication

How the scale indicates a low battery status.

Battery Recharging

Procedure for charging the scale's battery and its specifications.

Installation Guide

Rear Panel Access

Steps for safely removing and reinstalling the scale's rear panel.

Heartbeat LED Function

Explanation of the heartbeat LED's function and meaning.

Load Cell Connection

Power Connection and Fuse

RS232 and Remote Switch Connectivity

RS232 Terminal Block Details

RS232 DB9 Female Wiring

Diagram and description of DB9 female connector wiring for RS232 output.

RS232 DB9 Male Wiring

Diagram and description of DB9 male pin wiring for RS232 output.

Output Connections

Calibration Guide

Entering Calibration Mode

Methods to access calibration and setup modes via front panel or internal button.

Exiting Calibration Mode

Procedures to exit calibration and setup modes and save settings.

Setting Scale Capacity

Steps to set the scale's maximum capacity and unit of measure.

Setting Scale Count By

Scale Calibration Process

Calibration Error Codes

List of calibration error codes and their potential solutions.

Scale Calibration Troubleshooting

Scale Parameter Setup

Accessing Parameter Setup

Methods to access calibration and setup modes via front panel or internal button.

Exiting Parameter Setup

Procedures to exit calibration and setup modes and save settings.

Navigating Parameter Menus

How to navigate through parameter groups and settings.

Parameter Groups Overview

Capacity and Calibration Settings

Parameters related to scale capacity and calibration.

General Settings

Parameters for general scale settings and configurations.

Serial Port Configuration

Configuration settings for serial ports.

Network Connectivity Configuration

Configuration settings for Ethernet and wireless connectivity.

Bluetooth Configuration

Configuration settings for Bluetooth connectivity.

USB Configuration

Configuration settings for USB connectivity.

Legal for Trade Restrictions

Audit Counters

Software Revision Information

Capacity and Calibration Parameters

Capacity Adjustment

Range for adjusting the scale's capacity.

Count By Setup

Settings for scale resolution or division.

Calibration Mode Settings

Options for calibration zero and entering calibration weight.

Display Filter Settings

Setting to control the speed of digital filtering.

Automatic Zero Tracking Range

Motion Detection Settings

Motion Aperture

Determines how many divisions must change for motion to be detected.

Motion Delay

Sets the duration of motion indication display.

Start Up Zero Configuration

Zero on Demand Setting

Print on Demand Setting

Operating Mode Settings

Standard Operation Mode

Normal scale operation without legal-for-trade restrictions.

Legal-for-Trade Modes

Enables legal-for-trade modes with parameter restrictions.

Exiting Calibration and Setup

General Settings

Unit Enable;Disable

Determines which unit selections are active on the scale.

Startup Unit Selection

Configures the selection of startup units displayed on power up.

Push Button Configuration

Automatic Off Timer

Threshold Level Entry

Default Parameter Settings

AD Converter Counts

LED Brightness Control

Battery Operation Enable;Disable

Serial (RS232) Port 1 Configuration

Data Output Mode Port 1

Selects how data is transmitted from Serial Port 1.

Data Output Format Port 1

Defines the format of data transmitted from Serial Port 1.

Baud Rate Port 1

Sets the baud rate for Serial Port 1 communication.

Serial (RS232) Port 2 Configuration

Data Output Mode Port 2

Selects how data is transmitted from Serial Port 2.

Data Output Format Port 2

Defines the format of data transmitted from Serial Port 2.

Baud Rate Port 2

Sets the baud rate for Serial Port 2 communication.

Ethernet Connectivity

Ethernet Data Output Mode

Selects how data is transmitted via Ethernet.

Ethernet Data Output Format

Defines the format of data transmitted via Ethernet.

IP Address Assignment (Ethernet)

Assigns IP address settings for Ethernet.

Static IP Address Configuration

Subnet Mask Configuration

IP Gateway Configuration

TCP Port Number Setting

Ethernet MAC Address

Analog Output Adjustments

UDP IP Address Configuration

Wireless Ethernet Connectivity

Wi-Fi Data Output Mode

Selects how data is transmitted via Wi-Fi.

Wi-Fi Data Output Format

Defines the format of data transmitted via Wi-Fi.

IP Address Assignment (Wi-Fi)

Assigns IP address settings for Wi-Fi.

UDP Port Number (Wireless)

Idle Timeout Setting

Ethernet MAC Address

Wi-Fi Connection Status

Bluetooth Connectivity

Bluetooth Data Output Mode

Selects how data is transmitted via Bluetooth.

Bluetooth Data Output Format

Defines the format of data transmitted via Bluetooth.

USB Connectivity

USB Data Output Mode

Selects how data is transmitted via USB.

USB Data Output Format

Defines the format of data transmitted via USB.

Data Communications Overview

Transmit on Demand

Data transmission triggered by the PRINT button or remote switch.

Continuous Data Transmission

Data transmitted at regular intervals, showing motion status.

Auto Print Modes

Various Auto Print modes based on weight stability and thresholds.

Data Transmission Timers

Settings for timed data transmission intervals.

Data String Formatting

Standard Output Format Description

Details of the default data string format.

Sample Print String Examples

Examples of sample print strings for pounds and ounces.

Standard Output Formats

Basic Output Format

Description of the standard output data format.

Dual Unit Output Format

Format for printing dual units (lb and kg).

Label Printer Output Format

Format optimized for label printers.

Grs Unit Output Format

Format to print current weight, units, and 'grs'.

Custom Data String 1 Configuration

Custom Data String 2 Configuration

Custom Data String 3 Configuration

Custom Data String 4 Configuration

Custom Data String Configuration Details

Indicator Commands

Data Transmission Commands

Commands for transmitting weight data and custom strings.

Unit and Zero Commands

Commands to switch units and issue zero commands.

Model and Revision Commands

Commands to retrieve scale model and revision numbers.

Custom Data String Commands

Commands for loading and transmitting custom data strings.

WiFi Control Commands

Commands for managing WiFi connection and settings.

WiFi Status and Configuration Commands

Parameter Setting Commands

Request Parameter Settings

Command to request parameter values from calibration/setup menu.

Enter Parameter Data

Command to enter data into calibration/setup menu.

Remote Button Commands

Echo and Utility Commands

4-20 mA Analog Output Option

Analog Output Introduction

Overview of the 4-20mA analog output functionality.

Analog Output Setup

Instructions for calibrating the 4-20mA analog output.

Analog Output Operation

Effects of the 4-20mA option on scale operation and battery life.

Wired Ethernet Option

Wired Ethernet Specifications

Hardware and network interface specifications for the wired Ethernet option.

Wireless Ethernet Option

Wireless Ethernet Specifications

Hardware and network interface specifications for wireless Ethernet.

Wireless Regulatory Approval

FCC ID and compliance information for the wireless option.

Troubleshooting Wi-Fi

Confirming IP Configuration

Steps to verify IP address, subnet mask, and gateway settings.

Confirming Wi-Fi Connection

Steps to confirm the scale's Wi-Fi connection status.

Bluetooth Option Overview

Computer Setup for Bluetooth

Requirements for computer setup to connect with Bluetooth.

Bluetooth USB Dongle Recommendation

Recommendation for using Doran's USB Bluetooth dongle.

Scale Bluetooth Setup

Reference to parameter group for Bluetooth scale configuration.

Pairing Bluetooth Devices

Instructions for pairing the scale's Bluetooth module with a computer.

Bluetooth Module Specifications

Technical specifications for the Bluetooth module.

Bluetooth Pairing Instructions

Troubleshooting Common Problems

Weight Reading Repeatability Issues

Examines platform interferences and weigh bridge structure.

Scale Overload Issues

Checks overload stops and clearance for accurate capacity measurement.

Capacity Indication Issues

Checks for obstructions around load cells or spiders.

Zeroing Issues

Ensures scale stability and checks Zero on Demand/Display Filter.

Weight Reading Accuracy

Recommends checking scale accuracy with test weights and recalibrating.

Zero Drift Issues

Checks for air currents/vibration and suggests adjusting AZT parameter.

Bouncing Reading Issues

Checks for air currents/vibration and suggests changing Display Filter.

Scale Messages

Function Completion Messages

Indicates successful actions, cancellations, or saved parameters.

System Status Messages

Messages indicating button press duration or new firmware.

Error Messages

Overload and Underload Errors

Indicates scale capacity is exceeded or below minimum.

Gross Overload;Underload Errors

Indicates severe overload/underload potentially causing damage.

Startup and Circuit Errors

Errors related to startup stability, A/D circuit, or EEPROM corruption.

Program ROM and Calibration Errors

Program ROM Error

Indicates corruption of the scale's program memory.

Calibration Range Errors

Errors related to calibration zero, span, or motion instability.

Parameter Save and Capacity Errors

Errors indicating parameter save failure or incorrect capacity entry.

Default to Factory Settings

Doran 7000XL Series Specifications

General IconGeneral
BrandDoran