Do you have a question about the Doran 7000XL Series and is the answer not in the manual?
Instructions for safely unpacking the scale and precautions to prevent damage.
Indicates the current unit of measure displayed on the scale.
Indicates low battery charge and charging status.
Indicates when the scale is displaying a zero weight.
Indicates motion or instability of the weight on the platform.
Procedure for zeroing the scale and its function.
How to select and change the current unit of measure.
Function for transmitting data to external devices.
Methods for manually or automatically powering off the scale.
How the scale indicates a low battery status.
Procedure for charging the scale's battery and its specifications.
Steps for safely removing and reinstalling the scale's rear panel.
Explanation of the heartbeat LED's function and meaning.
Diagram and description of DB9 female connector wiring for RS232 output.
Diagram and description of DB9 male pin wiring for RS232 output.
Methods to access calibration and setup modes via front panel or internal button.
Procedures to exit calibration and setup modes and save settings.
Steps to set the scale's maximum capacity and unit of measure.
List of calibration error codes and their potential solutions.
Methods to access calibration and setup modes via front panel or internal button.
Procedures to exit calibration and setup modes and save settings.
How to navigate through parameter groups and settings.
Parameters related to scale capacity and calibration.
Parameters for general scale settings and configurations.
Configuration settings for serial ports.
Configuration settings for Ethernet and wireless connectivity.
Configuration settings for Bluetooth connectivity.
Configuration settings for USB connectivity.
Range for adjusting the scale's capacity.
Settings for scale resolution or division.
Options for calibration zero and entering calibration weight.
Setting to control the speed of digital filtering.
Determines how many divisions must change for motion to be detected.
Sets the duration of motion indication display.
Normal scale operation without legal-for-trade restrictions.
Enables legal-for-trade modes with parameter restrictions.
Determines which unit selections are active on the scale.
Configures the selection of startup units displayed on power up.
Selects how data is transmitted from Serial Port 1.
Defines the format of data transmitted from Serial Port 1.
Sets the baud rate for Serial Port 1 communication.
Selects how data is transmitted from Serial Port 2.
Defines the format of data transmitted from Serial Port 2.
Sets the baud rate for Serial Port 2 communication.
Selects how data is transmitted via Ethernet.
Defines the format of data transmitted via Ethernet.
Assigns IP address settings for Ethernet.
Selects how data is transmitted via Wi-Fi.
Defines the format of data transmitted via Wi-Fi.
Assigns IP address settings for Wi-Fi.
Selects how data is transmitted via Bluetooth.
Defines the format of data transmitted via Bluetooth.
Selects how data is transmitted via USB.
Defines the format of data transmitted via USB.
Data transmission triggered by the PRINT button or remote switch.
Data transmitted at regular intervals, showing motion status.
Various Auto Print modes based on weight stability and thresholds.
Settings for timed data transmission intervals.
Details of the default data string format.
Examples of sample print strings for pounds and ounces.
Description of the standard output data format.
Format for printing dual units (lb and kg).
Format optimized for label printers.
Format to print current weight, units, and 'grs'.
Commands for transmitting weight data and custom strings.
Commands to switch units and issue zero commands.
Commands to retrieve scale model and revision numbers.
Commands for loading and transmitting custom data strings.
Commands for managing WiFi connection and settings.
Command to request parameter values from calibration/setup menu.
Command to enter data into calibration/setup menu.
Overview of the 4-20mA analog output functionality.
Instructions for calibrating the 4-20mA analog output.
Effects of the 4-20mA option on scale operation and battery life.
Hardware and network interface specifications for the wired Ethernet option.
Hardware and network interface specifications for wireless Ethernet.
FCC ID and compliance information for the wireless option.
Steps to verify IP address, subnet mask, and gateway settings.
Steps to confirm the scale's Wi-Fi connection status.
Requirements for computer setup to connect with Bluetooth.
Recommendation for using Doran's USB Bluetooth dongle.
Reference to parameter group for Bluetooth scale configuration.
Instructions for pairing the scale's Bluetooth module with a computer.
Technical specifications for the Bluetooth module.
Examines platform interferences and weigh bridge structure.
Checks overload stops and clearance for accurate capacity measurement.
Checks for obstructions around load cells or spiders.
Ensures scale stability and checks Zero on Demand/Display Filter.
Recommends checking scale accuracy with test weights and recalibrating.
Checks for air currents/vibration and suggests adjusting AZT parameter.
Checks for air currents/vibration and suggests changing Display Filter.
Indicates successful actions, cancellations, or saved parameters.
Messages indicating button press duration or new firmware.
Indicates scale capacity is exceeded or below minimum.
Indicates severe overload/underload potentially causing damage.
Errors related to startup stability, A/D circuit, or EEPROM corruption.
Indicates corruption of the scale's program memory.
Errors related to calibration zero, span, or motion instability.
Errors indicating parameter save failure or incorrect capacity entry.
| Brand | Doran |
|---|---|
| Model | 7000XL Series |
| Category | Accessories |
| Language | English |