1. PREPARE FRAME AND INSTALL CLOSER
according to template. Fasten mounting
Prepare header 1 and side jamb 2
No. 8-32 pan head machine screws.
bracket 3 to side jamb with three
No. 10-32 flat head machine screws.
Fasten header to side jamb with two
washers. Install two fillister head machine
Fasten angle bracket 5 to closer with
two hex head machine screws and flat
7 , make approximately three turns.
screws 6 into mounting tabs on closer
remove spacer washers in mounting tabs.
Install closer into header by inserting
speed.
bracket with two 1/4-20 pan head machine
mounting tabs into mounting bracket 3 ,
then raise end of closer with angle
bracket 5 into header. Fasten angle
machine screws 6 securely.
screws. Closer should remain centered in
header. Tighten the two fillister head
head machine screws provided.
Install cover plate 8 by sliding tab
into frame and fasten opposite end to
mounting bracket with two No. 8-32 flat
Prepare top of door according to template.
2. PREPARE TOP OF DOOR AND INSTALL CLOSER ARM
interior of building. Fasten adjustment
NOTE: Cut-out side of door should face
closer arm 11 . Place closer arm over
stud 9 to door channel. Install two
1/4-20 hex head alignment screws 10 into
1/4-20 hex head alignment screws 10
adjustment stud 9 in door channel.
Center arm in door, turning both
against door channel. Thread lateral
counterclockwise until they are wedged
washer 14 .
adjustment screw 12 into adjustment
stud 9 . Secure arm 11 into place
with 1/4-20 flat head screw 13 and flat
3. PREPARE BOTTOM OF DOOR AND INSTALL PIVOT
NOTE: For RTS 88 models only - do not
Prepare bottom of door according to
template. Fasten door portion of bottom
pivot with three 1/4-20 pan head machine
screws. Prepare floor or threshold
according to template. Fasten floor
portion 16 with three No. 12 flat head
wood screws and plastic anchors. If
threshold is used, fasten threshold
portion 17 of bottom pivot with 1/2"
jamb nut 18 .
4. INSTALL DOOR
With door parallel to opening, place
bottom of door onto floor or threshold
portion of pivot. Push door to vertical
position until closer spindle is
completely engaged into closer arm 11 .
Fasten clamping block 19 to arm 11
with three 1/4-20 socket head cap
screws 20 . NOTE: Alternate fastening
screws when tightening clamping block.
TIGHTEN SECURELY! Fasten cover plate 21
to door with screws provided.
5. ADJUST CLOSING SPEEDS
Valve "A" - Controls closing speed
from maximum opening angle to 0° .
Clockwise turns decrease closing speed,
counterclockwise turns increase closing
Valve "B" - Increases closing speed
BRACKET SIDE LOAD ALUMINUM DOOR AND FRAME
from maximum opening angle to 20° ,
turn valve counterclockwise.
6. DOOR ALIGNMENT
Double Acting - Center door in frame by
loosening 1/4-20 flat head screw 13
and adjusting the two 1/4-20 hex head
alignment screws 10 as required. To
adjust clearance between door and frame,
adjust lateral adjustment screw 12 .
Retighten 1/4-20 flat head screw 13 .
TIGHTEN SECURELY!
Single Acting - Adjust arm to insure that
door closes tightly against stop. Loosen
1/4-20 flat head machine screw 13 .
Adjust closer arm fully in the direction
of door swing. To adjust clearances
between door and frame, adjust lateral
adjustment screw 12 . Retighten 1/4-20
flat head screw 13 . TIGHTEN SECURELY!
7. CLEARANCE ADJUSTMENTS (IF REQUIRED)
If clearances differ from those shown on
template, adjust in the following manner.
Adjustable pivot art no. 8570, 8572 - open
door to approximately 90° . Loosen clamping
block 19 on closer arm. With small flat
blade screwdriver, turn height adjustment
screw 22 through 3/8" diameter clearance
hole in heel edge of door. Clockwise turns
raise door, counterclockwise turns lower
door. Retighten clamping block 19 .
TIGHTEN SECURELY!
8. DOOR REMOVAL
Remove cover plate 21 from side of door.
Remove clamping block 19 from top arm.
Lean top of door out until it clears
frame. Lift door off of bottom pivot.
VALVE "A"
VALVE "B"
20°
"A"
"B"
RTS SERIES PACKAGE 01, 02 WITH SLOTTED ANGLE
INSPK NO. 08280320 Rev.12/08
1 of 2
INS NO.
Rev.
08280321
12/08
PAGE
www.dorma-usa.com 1-800-523-8483
All manuals and user guides at all-guides.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma RTS Series and is the answer not in the manual?

Dorma RTS Series Specifications

General IconGeneral
BrandDorma
ModelRTS Series
CategoryDoor locks
LanguageEnglish

Related product manuals