Table of Contents

Questions and Answers

  • D
    Douglas Nguyen Jr.Aug 19, 2025
    Why is my Doseuro Water Pump making excessive noise?
    • F
      frosalesAug 19, 2025
      Excessive noise in your Doseuro Water Pump can be attributed to: * Air entering the pump head. Verify the suction pipe for inlet air and check pipe junctions and seals. * Foreign material inside the valve. Inspect and clean or replace valve units. * Excessive lifting of valves. Replace any worn parts. * Noise caused by the safety relief valve or other accessories in the discharge pipe. A pulsation dampener before the back pressure valve or a different type of valve may be needed.
  • J
    Jennifer SmithAug 29, 2025
    What to do if pumped liquid comes out from the hole under the lantern of Doseuro FM 50N-50 Water Pump?
    • A
      April BarrettAug 30, 2025
      If pumped liquid is coming out from the hole under the lantern of your Doseuro Water Pump, the diaphragm is likely broken. Replace the diaphragm and assess other components for damage, replacing them as needed.
  • K
    kparkNov 7, 2025
    Why Doseuro Water Pump has low discharge pressure and low flow rate?
    • A
      Anne GuerreroNov 8, 2025
      The Doseuro Water Pump might have low discharge pressure and flow rate due to several reasons: * A clogged suction system. Clean the suction filter and check for obstructions. * A worn safety relief/vent valve seat. Inspect the valve for leaks. * The pump is not completely primed, with an air bubble in the suction pipe. Ensure correct suction height, respecting the NPSHr value, and consider installing a suction lung. * Incorrectly connected motor. Verify the motor plate for correct wiring and check the phases. * Dirty pump valves. Inspect, clean, or replace valve components. * Air entering the pump head. Check for inlet air in the suction pipe, pipe junctions, valve stem seals, and instrument connections. Also, check the diameter and piping route. * Insufficient suction pre...

Summary

Safety Standards During Use

Using the Dosing Pumps

Destination of Use

Defines the intended application and warns against misuse.

Intended and Non-intended Use of the Pump

Details the pump's intended applications and restrictions, like explosive atmospheres.

Technical Data of Pump

Presents characteristic technical data for different pump models.

Pump Installation

Pump Connection to Plant Piping

Suction Pipe Connection

Provides essential suggestions for correct suction pipe installation.

Discharge Pipe Connection

Gives important suggestions for the proper realization of the discharge pipe.

Electrical Connection

Motor Connection

Instructions for connecting the motor, including voltage, frequency, and earthing.

Pump Adjustment

Stroke Variation with Manual System

Details how to adjust the pump's flow rate using the manual stroke system.

Procedure Before Start-Up

Commissioning

Steps for commissioning the pump after initial checks, including flow rate adjustment.

Inconveniences Upon Commissioning

Discusses common issues encountered during commissioning and their solutions.

Maintenance

Preventive Maintenance

Noisy Mechanics with Vibrations

Addresses troubleshooting for abnormal noise and vibrations in the pump mechanics.

Verification of Pump Flow Rate

Explains how to verify the pump's flow rate curve against adjustments.

Pressure

Discusses pressure monitoring, risks of overpressure, and crystallisation.

Routine Maintenance

Maintenance Procedures

Outlines necessary precautions before performing maintenance on the pump.

Operations on the Pump Head

Troubleshooting

Provides a table of common inconveniences, their causes, and solutions.

Pump Head Disassembly and Diaphragm Replacement

Step-by-step guide for disassembling the pump head and replacing the diaphragm.