Rack Monitor 88XX
Document: Operation Manual
Date: January 2024
Version: A.0 subject to change
Page 14 of 43 Operations Manual
Figure 2
Monitor indicators react differently if the dipswitch setting (1-6) isn’t set and in the default off position.
A LED test will be started after power-up.
There should be nothing connected at power-up. A system error pattern will be shown if sensors are connected
during power-up. System error light pattern Top bar flashing Red and Bottom bar will flash code 13 ( see flash
pattern table below).
Flash Pattern Table
It is recommended to use a 88XX rack monitor to minimize downtime in case of an error. The 88XX rack monitor is
equipped with a OLED display and 20 multi-color LED indicators to visualize the status of the Rack monitor, Tank
truck and sensors. The 88X1E is not equipped with and display and 20 multi-color LED indicators and has only two
multi-color light bars.
Flash and color patterns are implemented to visualize the status of the 88X1E rack monitor, Tank truck and
sensors.
If the 88X1E is not in the 8130 emulation mode then the following light patters are used:
Long and short light pulses are indicating a number. A short (½ Sec.) pulse is 1 and a long (1½ Sec.) pulse is 5.
The pause between pulses is a ½ Sec. and the pause between iterations is 2 sec. e.g. a short pulse is 1. Two short
pulses is 2. Etc. A long pulse followed by one short pulse is 6.