Rack Monitor 88XX
Document: Operation Manual
Date: January 2024
Version: A.0 subject to change
Page 35 of 43 Operations Manual
Reset Counts
The reset counts keep track of the last reason why the Rack resets and the number of times the rack resets for
each reason. Everything is stored as an unsigned 16-bit value.
Register
Reset reason
19
Last reset reason for reset
20
Trap error
21
Illegal opcode
22
Configuration mismatch
23
External reset
24
Reset instruction
25
Watchdog
26
Brownout
27
Oscillator fail
28
Address error
29
Hard trap error
30
Stack error
31
Math error
32
DMA error
33
Soft trap error
Table 7 Reset counts
Vehicle ID
The vehicle ID is stored in 4 registers giving a total of 64 bits or 8 bytes. The first byte is the tag crc, register 35
through 37 are the 48-bit unique serial. Register 38 shows the family code and crc of the device. When the Rack is
still searching for a tag, or when there is no valid ground verification, all registers will contain the value 0xFFFF.
When there is no valid tag found all registers will contain the value 0x0000.
Register 35
Register 36
Register 37
Register 38
MSB
LSB
MSB
LSB
MSB
LSB
MSB
LSB
serial MSB
Serial LSB
Family code
Crc
Table 8 Vehicle ID
Probe Status
The probe status is given for any for each probe in the probe status registers.
Register 71
Register 72
Register 78
MSB
LSB
MSB
LSB
MSB
LSB
Probe
1
State
Probe
2
State
Probe
3
State
Probe
4
State
Probe
15
State
Probe
16
State
Table 9 Probe status registers