14. Leak Rate: The calculated leak rate in liters/gallons per hour.
Graphical User Interface
Refer to the PLLD section of M2052 LX 4 and LX Plus User Manual.
Pipe Data Tables
The data for some industry known pipes is shown below.
RIGID PIPE TYPES BETA Gals/inch Liters/cm Liters/mm
FIBERGLASS (2 INCH) 25000 0,017 0,0253 0,0025
FIBERGLASS (3 INCH) 25000 0,038 0,0566 0,0057
STEEL (2 INCH) 50000 0,016 0,0238 0,0024
COPPER (1 INCH, TYPE K) 55000 0,003 0,0045 0,0004
ADVANCED POLYMER TECHNOLOGY FLEXIBLE PIPE TYPES BETA Gals/inch Liters/cm Liters/mm
1.5-INCH (P150SC) 8800 0,008 0,0119 0,0012
1.75-INCH (P175SC) 7400 0,01 0,0149 0,0015
2.0-INCH (P200SC) 5600 0,014 0,0209 0,0021
2.5-INCH (P250SC) 4400 0,021 0,0313 0,0031
1.5-INCH (XP-150-SC) 5042 0,008 0,0119 0,0012
2.0-INCH (XP-200-SC) 5420 0,014 0,0209 0,0021
AMERON FLEXIBLE PIPE TYPES BETA Gals/inch Liters/cm Liters/mm
DUALOY 3000/FLS III 5400 0,008 0,0119 0,0012
DUALOY 3000/FLS III 7600 0,014 0,0209 0,0021
BRUGG FLEXIBLE PIPE TYPES BETA Gals/inch Liters/cm Liters/mm
FLEXWELL HL-40 (1.5 INCH) 33000 0,008 0,0119 0,0012
M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions 92