15
IC “Ice” – Auxiliary Freeze No action required. The pump(s) will
Sensor detects potential automatically activate regardless of spa
Freeze condition. status.
Cd “Cold Water” Temperature No action required. Freeze protection has
sensors detect a potential initiated as described above. (If pump 1 was
freeze condition. turned on due to this reason alone, this
message will appear for up to two minutes
right after very cold water is sensed.)
SA Spa is shut down. The If the problem persists, contact your dealer
sensor that is plugged or service organization. (May appear
into the Sensor “A” jack temporarily in an overheat situation and
is not working. disappear when the heater cools.)
Sb Spa is shut down. The If the problem persists, contact your dealer
sensor that is plugged or service organization. (May appear
into the Sensor “B” jack temporarily in an overheat situation and
is not working. disappear when the heater cools.)
Sn Sensors are out of balance. If the problem persists, contact your dealer
If alternating with spa or service organization.
temperature, it may just be
a temporary condition. If
flashing by itself, spa is shut
down.
HL A significant difference Check water level in spa. Refill if .
between temperature sensors necessary, if the water level is okay, make
has been detected. sure the pumps have been primed. If
This could indicate a problem persists, contact your dealer or.
flow problem. service organization
LF Persistent low flow Follow action required for “HL” message.
problems. (Display on the Turn spa off, then back to restore heating
fifth occurrence of “HL capability.
message.) Heater is shut
down, but other spa functions
continue to run normally.
dr Possible inadequate water, Check water level in spa. Refill if
poor flow, or air bubbles
necessary.
if water level is okay, make sure the
in the heater. Spa is shut pumps have been primed. Press any button
down for 15 minutes. to reset, or this message will automatically
reset within 15 minutes. If problem persists,
contact your dealer or service organization.