32
CAUTION
WARNING
Be Sure To Read And Fully Understand The Followings Before Use.
This product should be used only for 3 phase 220V motor.
One DPS unit should be used only for one motor that meets DPS specications.
3 phase voltages are output when the motor is running.
Connecting only U, W lines for control wires of eletronic switch, brake, magnetic
contactor, etc.
Only 1 phase of motor brake is allowed. (3 phase brake does not work.)
If the motor overheats, check the current indicated on the motor nameplate.
(Use motor load less than 80% of rated capacity of the motor.)
Never use DPS model that does not meet motor capacity. (causes motor overheating)
※
Never use DPS capacity 2 levels higher than rated motor capacity.
It may cause overheating or trouble.
ex) Motor 3HP: DPS MY-PS-5 model(o)
DPS MY-PS-7.5 model(×)
If you nd smoke, strange smell or noise, turn off the switch immediately, disconnect
the plug from the power socket, and contact our service center.
Continued use may cause re or electric shock.
■
■
■
■
■
■
■
■
Use this DPS only for operation 3 phase motor(220V) from single phase
power(220V) supply.
As the DPS has no protection device, install safety circuit breaker at the
input terminal to use it.
In the event of abnormality, cut off the power immediately.
(There is a danger of electric shock.)
Do not move or install the product in the condition with the
current owing or exposed. (There is a danger of electric shock.)
Be sure to cut off the power switch in the event of power failure during
operation. (When the power is restored, it restarts automatically, which may
cause an unexpected accident.)
Do not disassemble, assemble, or modify the DPS.
■
■
■
■
■
■