Inhalation Anesthesia Machine
Software 3.0n
Instructions for Use
Fabius
®
Tiro
دﯾﯾﺎﻣرﻓ ﮫﻌﺟارﻣ.WWW.ELM-FAN.IRتﯾﺎﺳ ﮫﺑ رﺗﺷﯾﺑ دراوﻣ دوﻠﻧاد یارﺑ
To download more items, go to ELM-FAN.IR

Other manuals for Dräger Medical Fabius Tiro

Question and Answer IconNeed help?

Do you have a question about the Dräger Medical Fabius Tiro and is the answer not in the manual?

Summary

Chapter 1 - Introduction

For Your Safety and that of Your Patients

Essential safety information for users and patients regarding the anesthesia machine.

General Warnings and Cautions

Critical warnings and cautions for safe operation, setup, and maintenance of the device.

Intended Use

Defines the proper application and purpose of the anesthesia machine.

Safety Features

Key safety features integrated into the anesthesia machine's design.

Symbol Definition

Explanation of various symbols used on the device labels and packaging.

Chapter 2 - Configurations and Components

Typical Fabius Tiro Configuration

Overview of the standard Fabius Tiro configuration options for various applications.

Components Overview

Lists and describes the main components of the Fabius Tiro system.

Optional Components

Details on optional accessories like vaporizers, adapters, and flowmeters.

Recommended Device Configurations

Examples of recommended device configurations for system integration.

Chapter 3 - Operating Concept

Standard Function Controls

Explanation of basic controls like Home, Power LED, and rotary knob.

Monitoring Functions

Details on monitoring controls, LED indicators, and alarm silencing.

Ventilation Modes and Controls

Explanation of ventilation screens, modes, controls, and parameters.

Fresh Gas Control

Information on controlling and monitoring fresh gas flow rates and pressures.

APL Valve Operation

Explanation of the Adjustable Pressure Limiting (APL) valve functions.

Chapter 4 - Preparation

Mounting and Setup Procedures

Instructions for mounting the machine and accessing its panels.

Gas Supply Connections

Detailed instructions for connecting medical gas pipeline supplies.

Electrical and Battery Setup

Steps for activating the battery and connecting to mains power.

Component Installation

Steps for attaching essential components like valves and the CO2 absorber.

System Connections

Procedures for connecting breathing hoses, sensors, and breathing systems.

HBSPS Installation (Optional)

Instructions for installing the optional Heated Breathing System Power Supply.

Daily and Pre-use Checkout

Information and procedures for the daily and pre-use checkout process.

Chapter 5 - Operation and Shut-down

Power-Up and Initial Operation

Description of the power-up screen, self-diagnostics, and initial startup.

System Operation Procedures

Details on operating the vaporizer, O2 flush, and replacing CO2 absorbent.

Power Failure and Backup

Information on battery backup and behavior during power interruptions.

Ventilator Fail State and Override

Procedures for ventilator fail state and manual override.

Transport and Storage Preparation

Procedures for preparing the machine for transport or storage.

Chapter 6 - Monitoring

Alarm System Overview

General information about alarms, tones, and text conventions.

Oxygen Monitoring Details

Explanation of oxygen monitoring functions, windows, and calibration.

Respiratory Volume Monitoring

Information on measuring respiratory volume, including displays and controls.

Breathing Pressure Monitoring

Details on breathing pressure monitoring, displays, controls, and alarms.

Chapter 7 - Setup Window (Used During Operation)

Setup Window Access and Navigation

How to access and navigate the Setup window for various functions.

Alarm Configuration

How to manage volume alarms and access alarm logs/volumes.

Sensor Calibration Procedures

Step-by-step guides for calibrating O2 and flow sensors.

Desflurane Compensation Settings

How to activate and manage Desflurane compensation for accuracy.

Chapter 8 - Standby Mode Functions

Standby Screen Navigation

Instructions for accessing and confirming the Standby screen.

System Tests and Calibration

Procedures for running system tests and calibrating sensors.

Default Settings Configuration

Accessing and setting default configuration parameters.

Alarm Limit and Volume Settings

How to set default alarm limits and alarm volume.

Chapter 9 - Routine Maintenance and Cleaning

General Maintenance and Disposal

Guidelines for routine maintenance, disposal of parts, and disassembly.

Component Dismantling Procedures

Steps for dismantling various components like valves, sensors, and canisters.

Disinfection and Cleaning Protocols

Protocols for cleaning, disinfecting, and autoclaving system components.

Maintenance Intervals and Checks

Recommended intervals for inspection, service, and readiness checks.

Chapter 10 - Troubleshooting

Alarm Message Resolution Table

Comprehensive table of alarm messages, probable causes, and remedies.

Chapter 11 - Components

Component Identification

Visual identification of key components on the machine's front and rear.

Gas Supply Connection Points

Identification and diagrams of all gas supply connection points.

Chapter 12 - Technical Data

Machine and Environmental Specifications

Technical data on ambient conditions, machine specs, and electrical safety.

Ventilator and Breathing System Data

Technical specifications for the ventilator and breathing systems.

Vaporizer and Interface Data

Technical data related to anesthetic agent vaporizers and interfaces.

Diagrams and Schematics

Collection of diagrams illustrating gas flow and internal systems.

Appendix - Daily and Preuse Checkout Form

Pre-Use System Checks

Procedures for pre-use verification of system connections and functions.

Gas Circuit Leak Testing

Procedures for leak testing the compact breathing and fresh gas circuits.

Ventilator and Monitor Checks

Checks for proper ventilator operation and monitor alarm functions.

Dräger Medical Fabius Tiro Specifications

General IconGeneral
TypeAnesthesia Workstation
ManufacturerDräger Medical
ModelFabius Tiro
Gas SupplyO2, N2O, Air
Integrated VentilatorYes
Tidal Volume Range20 to 1400 mL
PEEP0 to 20 cmH2O
I:E Ratio4:1 to 1:4
Pressure LimitationAdjustable
Ventilation ModesSIMV
Inspiratory PressureUp to 70 cmH2O
Inspiratory Time0.2 - 5.0 s
Respiratory Rate4 to 60 bpm
FlowmetersO2 and N2O
Vaporizer Mount2 mounts for Dräger vaporizers
AbsorberClic absorber
Display6.5 inch TFT color screen
Power Supply100 - 240 VAC, 50/60 Hz
Backup BatteryApprox. 45 min (depending on ventilation settings and battery condition)
AlarmsAudible and visual alarms
CompatibilityCompatible with Dräger monitoring systems