Dräger Medical Titus User Manual

Dräger Medical Titus
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Titus
Tragbares Anästhesiegerät
Portable Anaesthetic Machine
Gebrauchsanweisung
Instructions for Use
1-131-95

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Dräger Medical Titus and is the answer not in the manual?

Dräger Medical Titus Specifications

General IconGeneral
CategoryMedical Equipment
ManufacturerDräger Medical
ModelTitus
TypeAnesthesia Machine
Power Supply100 – 240 VAC, 50/60 Hz
Gas SupplyO2, N2O, Air
Ventilation ModesSIMV
PEEP0-20 cmH2O
Oxygen Concentration21-100%
Vaporizer MountsUp to 2
Monitoringoxygen concentration
DisplayColor screen

Summary

Safety and General Information

Strictly Follow the Instructions for Use

Emphasizes understanding and adhering to the manual for safe operation.

Handling Compressed Gas Cylinders

Device Intended Use and General Usage

Model Description and Assembly

Assembling the Titus Machine

Advises on handling the machine during assembly and avoiding excessive tilting.

Gas Supply Connections

Explains how to connect the machine to gas sources, including recommendations for 'Air'.

Gas Supply Configurations

Details connecting to a central supply system or using gas cylinders.

Portable Cylinder Pack Gas Supply

Describes gas supply from a portable cylinder pack for mobile and emergency use.

Circle System Assembly and Volume Measurement

Guides on assembling the circle system, including CO2 absorber and valves.

Ventilog Compressed Gas Supply

Explains how to supply Ventilog with compressed gas, including placement and safety warnings.

Fitting the Vaporiser

Details how to attach the plug-in vaporiser to the anaesthetic machine.

Installing Monitoring Sensors

Details the installation of sensors for volume, pressure, and O2 measurement.

Gas Monitoring Connections

Explains how to connect monitors for CO2 and anaesthetic gas concentration.

Emergency Use and Pre-Use Checks

Guides on connecting the Magill inhalation device for emergency use.

MRI Operation and Specific Checks

MRI Safety Regulations and Recommendations

Outlines critical safety measures for operating the device in an MRI environment.

Operation, Checks, Maintenance, and Technical Data

Equipment Check Procedure

Explains how to prepare and use the plastic checklist for pre-use checks.

Performing Pre-Use Checks

Stresses the importance of performing checks before every use and how to record them.

Detailed Equipment Check Requirements

Outlines prerequisites and tests for the gas supply, flowmeters, and S-ORC function.

Managing Gas Supply Failures

Provides steps to rectify gas supply disruptions or manage failures.

Titus Anaesthetic Apparatus Care List

Provides a comprehensive list of components and their required cleaning/sterilization intervals.

Service and Maintenance Intervals

Lists intervals for apparatus inspection, safety checks, and component replacement by experts.

Specific Readiness Checks: Alarms, S-ORC, Gas Type

Details how to test the O2 shortage alarm and N2O cut-out mechanism.

S-ORC Functionality Checks

Explains how to test the S-ORC's function in limiting N2O flow based on O2 concentration.

Low-Pressure System Leak Testing

Explains how to perform a leak test on the low-pressure system with and without the Vapor.

Safety Features Overview

Describes safety features like O2 shortage alarms and the O2 ratio controller (S-ORC).