Plus and PSS Series - Lung Demand Valve
tm 1285.001 - August 2001
6:2
6.1 Test Procedures
The Plus and PSS Series range of Lung Demand Valves are approved for
use with approved Dräger Compressed Air Breathing Equipment
(C.A.B.E.)
Standard test procedures for C.A.B.E. are as follows and are covered in
the relevant Training Manual for the C.A.B.E.
! Cylinder Pressure Check and Valve Leak Test
! High Pressure Leak Test
! Whistle Warning Unit Test
! Full Flow Test
! Medium Pressure Test - Pressure Reducer
For detailed instructions of the following Functional Tests relating to the
testing of the lung demand valve and associated ancillary items refer
to the appropriate Test Equipment Manual.
Type A and AE
! Balanced Piston Leak Test
! Positive Pressure Balance Test
! Static Pressure Test
! Positive Pressure Switch Over
Type N
! Balanced Piston Leak Test
! Demand Valve Opening Pressure

Other manuals for Dräger PSS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger PSS Series and is the answer not in the manual?

Dräger PSS Series Specifications

General IconGeneral
TypeSelf-Contained Breathing Apparatus (SCBA)
MaterialStainless steel
Breathing GasCompressed air
DurationVaries by cylinder capacity and breathing rate
Cylinder MaterialAluminum or composite
CommunicationIntegrated communication system (optional)
Operating pressureUp to 300 bar (4350 psi)