INTRODUCTION
In cases where a forced ‘service interval’ is required, a
service warning feature can be selected and programmed
by the installer only. This feature will reduce the comfort
level of the dwelling by a cycling controlled method,
The heating will run only for the first 15 mins of each hour
during the programmed time
The hot water will run only for the first 13 mins of each hour
during the programmed time.
FUNCTION
The required ‘service’ date must be set, by entering the
‘number of days’ from now to when the next service is
due and the alarm must be selected (if required)
30 days before the total ‘number of days’ have elapsed
the following warning will be shown on the display of the
programmer,
SERVICE, then...
DUE, then...
DUAL
CHANNEL
SINGLE
CHANNEL
SERVICE INTERVAL INSTRUCTIONS
For use with
for heating OR hot water
LP111Si, LP711Si
LP241Si, LP522Si, LP722Si
for heating AND hot water
FOR THE INSTALLER/SERVICE ENGINEER ONLY!
DO NOT LEAVE WITH END USER!
SINGLE
CHANNEL
Timeswitch
DUAL
CHANNEL
Programmer
SERVICE INTERVAL
Lifestyle
FUNCTION Cont...
25th DEC, then...
Todays time
The backlight will flash to draw attention!
This sequence will cycle continuously for 30 days until the preset
‘service date’ (‘number of days’) is reached.
When the ‘service date’ (‘number of days’) is reached the
display will show
SERVICE
Both the LCD and backlight will flash to draw attention!
The programmer will be functioning in the ‘reduced comfort’
mode as described earlier
All normal programmer functions will be disabled
An audible alarm will sound
The alarm can be put into ‘snooze’
for 24hrs by pressing any button
The programmer can only be returned to normal operation
by re-setting with the ‘LPSi – Reset Unit’
INSTALLER/SERVICE ENGINEER INSTRUCTIONS
Setting the Service Interval Features
NOTE: ENSURE THE TIME & DATE ARE SET CORRECTLY BEFORE
SETTING/CONFIRMING THE SERVICE INTERVAL SETTINGS
To access the menu, on the LPxxxSi unit, for the service interval
feature press the ‘-‘ (minus) button for longer than 8 (eight)
seconds and the display should show,
If the programmer is in the Service mode, i.e.SEr permanently
displayed then you will have to reset the programmer by
positioning the reset unit as shown below and pressing the
button before the service interval menu can be accessed.
Press the ‘+’ (plus) button to switch the ‘service interval’
feature on or off.
Press the SET? Button to confirm this setting. The display
should now show,
Press the ‘+’ (plus) button to switch the ‘audible alarm feature
on or off. The alarm will sound after the 30 day warning period
is complete and the service is due
Question and Answer IconNeed help?

Do you have a question about the Drayton Lifestyle LP522Si and is the answer not in the manual?

Drayton Lifestyle LP522Si Specifications

General IconGeneral
BrandDrayton
ModelLifestyle LP522Si
CategoryTemperature Controller
LanguageEnglish

Summary

Service Interval Instructions

Single Channel Timeswitch

Describes the single-channel Timeswitch model for service interval programming.

Dual Channel Programmer

Describes the dual-channel Programmer model for service interval programming.

Introduction to Service Interval

Explains the purpose and effect of the forced service interval feature on dwelling comfort.

Function of Service Interval

Details how the service interval feature affects heating and hot water run times.

Service Interval Function Details

Service Date Warning Display

Describes the visual and audible alerts when the service date is approaching or reached.

Reduced Comfort Mode Operation

Details the 'reduced comfort' mode, disabled functions, and audible alarm.

Exiting Service Mode

Explains how to return the programmer to normal operation using the Reset Unit.

Installer Service Interval Setup

Setting Service Interval Features

Guides on accessing the service interval menu and setting its features.

Configuring Service Interval

Instructions for switching the service interval on/off and confirming settings.

Setting Audible Alarm

Explains how to enable or disable the audible alarm feature for service warnings.

Service Interval Confirmation and Reset

Confirming Service Settings

Details confirming settings like audible alarm and service interval in days.

Setting Service Interval Duration

Procedure for setting the required service interval in days.

Service Interval Reset Procedure

Guides on using the reset unit to confirm settings and reset the counter.

Reset Signal Transmission

Explains the timing and method for sending the reset signal with the handheld unit.

Reset Outcome and Failure

Describes the expected display after reset and the consequence of failed signal reception.

Reset Unit Battery Replacement

Changing the Battery

Instructions for accessing and replacing the battery in the service interval reset unit.

Battery Disposal

Guidance on the proper and careful disposal of the used battery.

Related product manuals