EasyManua.ls Logo

Dreizler marathon M 5001 - User Manual

Default Icon
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MANUAL
marathon
®
burners
hightech low emission
gas burner
Subject to technical modifications
without notice!

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Dreizler marathon M 5001 and is the answer not in the manual?

Summary

Safety Instructions

Burner Construction in Marathon Gas Burners

Burner Construction in Gas and Dual Fuel Burners Model MONObloc

Burner Construction in Gas and Dual Fuel Burners Model DUObloc M;MC 10003

Operations Manual for Marathon Gas Burner

Commissioning Procedures for Marathon Gas Burner

Prerequisites for First Commissioning

Conditions required before initial burner setup.

Preparation for First Commissioning

Steps to take before the actual burner commissioning process.

Commissioning

The process of starting up and commissioning the burner.

Settings for Marathon Burner with Pneumatic Linkage

Description and Functionality of the Pneumatic Linkage

Explanation of how the pneumatic linkage controls gas and air.

Presetting of the Motorised Air Damper (Pressure Side) for MAX Load

Adjusting the air damper for maximum load conditions.

Presetting the Manual Damper for Maximum Load (Suction Side)

Setting the manual damper for maximum load.

Setting Burner Load

Procedure for setting the burner's load capacity.

Presetting of the Motorised Air Damper (Pressure Side) for MIN Load

Adjusting the air damper for minimum load conditions.

Setting Minimal Burner Load

Procedure for setting the minimum burner load.

Gas;Air Ratio Control with Pneumatic Linkage

Description of Gas;Air Ratio Control

Explanation of how the gas and air ratio is controlled pneumatically.

Functionality of Gas;Air Ratio Control

How the pneumatic gas/air ratio control system automatically compensates parameters.

Instructions for the Configuration of the Gas;Air Ratio Control

Steps to configure the gas/air ratio control system.

Settings for Burner with Electronic Linkage

Presetting the Gas and Air Damper by Way of the Servomotor

Setting gas and air dampers using the servomotor.

Adjustment of the Operation Distance of the Speed Transmitter

Adjusting the operating distance for the speed transmitter.

Settings for the Potentiometer

Configuration settings for the potentiometer.

Configuring the Frequency Converter

Setting up the frequency converter and allocating frequencies.

Configuring the Load Point

Setting the required operating points for the load.

Settings for Marathon Burners with Mechanical Linkage

Preadjustment the Gas and Air Dampers for Small Loads (MIN)

Setting the gas and air dampers for minimum load.

Preadjustment the Gas and Air Dampers for Full Loads (MAX)

Setting the gas and air dampers for maximum load.

Basic Settings for Gas and Air Damper

Fundamental settings for the gas and air damper.

First Start-Up of the Burner on the Boiler

Procedure for the initial startup of the burner.

Burner Adjustments

Adjusting the burner for optimal performance.

Adjustment of Combustion Air in Position MIN (Small Load)

Adjusting combustion air for small load conditions.

Fine Tuning the Gas and Air Volume

Optimizing the gas and air flow rates for correct mixture.

Final Check

Final checks before handover and verification of thermostat function.

Decommissioning a Marathon Gas or Dual Fuel Burner

The Air Damper

Configuration of the Ring Air Damper

Servomotor Type SQN 7...

Servomotor Type SQN 3...

Servomotor Type SQM 5...

Function

How the SQM 5 servomotor operates.

Ignition and Flame Monitoring of Gas Burners Marathon M...

Ignition Transformer

Nozzle Assembly in Marathon Gas Burners

Gas Ramp Dimensioning for Gas Burners

Mounting Gas Ramps

Installation and Dismantling of Fan Impeller with Fixed Hub in Monobloc Burners

Installation and Dismantling of Fan Impeller in Duobloc Burners

Gas Low Pressure Protection (Gas Pressure Switch MIN)

Function of Gas Pressure Switch MIN

How the gas pressure switch MIN functions.

Configuring the Gas Pressure Switch MIN

Steps to configure the gas pressure switch MIN.

Installation Type Gas Pressure Switch MIN

Information on the installation type of the MIN pressure switch.

Gas High-Pressure Overload Protection (Gas Pressure Switch MAX)

Function of Gas Pressure Switch MAX

How the gas pressure switch MAX functions.

Configuring the Gas Pressure Switch MAX

Steps to configure the gas pressure switch MAX.

Installation Type Gas Pressure Switch MAX

Information on the installation type of the MAX pressure switch.

Air Pressure Switch

Function of the Air Pressure Switch

How the air pressure switch functions.

Configuring the Air Pressure Switch

Steps to configure the air pressure switch.

Marathon Gas Burner Model with Air Pressure Switch

Details on Marathon gas burners equipped with air pressure switches.

Motors with Relubrication System

Frequency Converter frequency

Dreizler Burner Control Unit Quattro Pro for Modulating Marathon Burners

Description

Overview of the quattro pro control unit's capabilities.

Operation

Information on operating the quattro pro control unit.

Basic Configuration of Burner Controller RWF40

Configuring the Controller with a Pressure Sensor

Steps to configure the controller using a pressure sensor.

Basic Configuration of Burner Controller RWF 55

Configuring the Controller with a Temperature Sensor

Setting up the RWF 55 controller with a temperature sensor.

Troubleshooting in Marathon Gas and Dual Fuel Burners

Basic Calculations

Measuring Report and Calculations

Test Report in Compliance with DIN EN 676 for Gas Burners

Maintenance

Maintenance Work

List of essential maintenance tasks for the burner system.

Reference Values for Starting Torque

Torque values for screws and threaded plugs.

Work Sheet - Maintenance and Firing Systems

Maintenance Report

Annual Inspection and Maintenance

Annual Maintenance and Replacement of Safety-Relevant Components

Guidelines for annual maintenance and replacement of safety components.

Replacement of Safety-Relevant Components

Guidelines on when to replace safety-relevant components.

Dreizler marathon M 5001 Specifications

General IconGeneral
BrandDreizler
Modelmarathon M 5001
CategoryBurner
LanguageEnglish

Related product manuals