8
2.4 Standard Drive Ratings
Model CC-204 CC-207 CC-215 CC-222 CC-237 CC-255 CC-275 CC-2110 CC-2150 CC-2220
Motor Rating (KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.2 15 22.4
Constant Torque Motor
Rating (HP)(2)
0.5 1 2 3 5 7.5 10 15 20 30
Constant Torque Rated
Current (A) (1)
3.1 4.5 7.5 10.5 17.5 26 35 52 70 105
Rated Output (KVA) 1.2 1.7 2.9 4.2 7 10.3 13.9 20 28 41.7
Weight (lbs) 4.8 4.8 4.8 12.1 12.8 20.7 22 42.9 47.3 49.5
Input Voltage 1/3 phase, 200-240VAC (+/- 10%), 50-60 Hz (+/- 5%) 3 phase, 200-240 VAC (+ / - 10%), 50/60 Hz (+ / - 5%)
Output Voltage 3 phase, 200-240 VAC
Model CC-404 CC-407 CC-415 CC-422 CC-437 CC-455 CC-475 CC-4110 CC-4150 CC-4220
Motor Rating (KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11.2 15 22.4
Constant Torque Motor
Rating (HP)(2)
0.5 1 2 3 5 7.5 10 15 20 30
Constant Torque Rated
Current (A) (1)
1.5 2.3 3.8 5.2 8.8 13 17.5 26 35 52
Rated Output (KVA) 1.2 1.7 2.9 4.2 7 10.3 13.9 20 28 41.7
Weight (lbs.) 9.2 9.2 9.2 9.2 18.5 22 22 45.1 47.3 49.5
Input Voltage 3 phase, 380-460 VAC (+ / - 10%), 50/60 Hz (+ / - 5%)
Output Voltage 3 phase, 380-460 VAC
(1) 150% overload for 120 seconds
(2) Horsepower and current ratings based on CMAA class A-D use for traverse or hoist
operation with a mechanical load brake. Consult Drivecon for other service classes. Always
choose inverters based on peak current draw of motor to be within the overload rating of the
drive.
Table 2.4a 230V Crane Commander Ratings
Table 2.4b 460V Crane Commander Ratings